Reasons to Replace a Proportional Counter (PC) in the Wavelength Dispersive Spectrometer (WDS) with a Silicon Drift Detector (SDD)
نویسندگان
چکیده
منابع مشابه
The C.A.T. Pixel Proportional Gas Counter Detector
A simple geometry of real pixel gas detectors has been evaluated that circumvents the limitations of a microstrips, namely aging, gain drift and flux limitation due to the dielectric charging. A good resolution has been obtained while preserving a large active size and a high gain and counting rate capabilities.
متن کاملPerforming elemental microanalysis with high accuracy and high precision by scanning electron microscopy/silicon drift detector energy-dispersive X-ray spectrometry (SEM/SDD-EDS).
Electron-excited X-ray microanalysis performed in the scanning electron microscope with energy-dispersive X-ray spectrometry (EDS) is a core technique for characterization of the microstructure of materials. The recent advances in EDS performance with the silicon drift detector (SDD) enable accuracy and precision equivalent to that of the high spectral resolution wavelength-dispersive spectrome...
متن کاملWavelength Dispersive Spectrometer and Energy Dispersive Spectrometer Automation: Past and Future Development.
As part of the Microbeam Analysis Society (MAS) symposium marking 50 years of electron microprobe analysis, this article reviews the important advances made over the decades to the automation of data collection and computerized analysis of data from the electron microprobe. Out of many innovations that contributed to the advance of microprobe automation, we have chosen to focus on a few develop...
متن کاملfrom linguistics to literature: a linguistic approach to the study of linguistic deviations in the turkish divan of shahriar
chapter i provides an overview of structural linguistics and touches upon the saussurean dichotomies with the final goal of exploring their relevance to the stylistic studies of literature. to provide evidence for the singificance of the study, chapter ii deals with the controversial issue of linguistics and literature, and presents opposing views which, at the same time, have been central to t...
15 صفحه اولThe gas proportional scintillation counter / microstrip gas chamber hybrid detector
The gas proportional scintillation counter/microstrip gas chamber (GPSC/MSGC) hybrid detector for X-ray spectrometry is described. The detector uses a CsI-coated microstrip plate placed in direct contact with the gas-filling as the photosensor readout for the GPSC scintillation substituting for the photomultiplier tube (PMT). Usable photosensor maximum gain is limited by optical positive feedba...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Microscopy and Microanalysis
سال: 2020
ISSN: 1431-9276,1435-8115
DOI: 10.1017/s1431927620015779