REASONABLE EVALUATION OF PILE SOUNDNESS BASED ON PILE INTEGRITY TEST

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interpretation of static pile loading test results and application for design of pile groups

Recent major bridge projects in the Greater Vancouver Area showcase the experience of local geotechnical engineers. Large static pile loading tests have been carried out on a number of these projects including the Pitt River Bridge, Golden Ears Bridge and Port Mann Bridge projects. This paper briefly discusses different analytical approaches to load test interpretation and reviews the approach ...

متن کامل

Integrity Testing of Pile Cover Using Distributed Fibre Optic Sensing

The integrity of cast-in-place foundation piles is a major concern in geotechnical engineering. In this study, distributed fibre optic sensing (DFOS) cables, embedded in a pile during concreting, are used to measure the changes in concrete curing temperature profile to infer concrete cover thickness through modelling of heat transfer processes within the concrete and adjacent ground. A field tr...

متن کامل

Research on Pressed Pile Test and Finite Element Analysis of Large-diameter Steel Pipe Pile of Zhanjiang Port

In order to study pressed pile test and ultimate bearing capacity character of large-diameter steel pipe pile, based on two high-piled wharfs of Zhanjiang Port, pressed pile test and numerical simulation of three large-diameter steel pipe piles are analyzed in this paper. Anchored pile method is used to pressed pile test, and the curves of Q-s and ultimate bearing capacity are attained. Then th...

متن کامل

Effect of Passive Pile on 3D Ground Deformation and on Active Pile Response

Using a series of model tests, this study investigated the effect of a passive pile on 3D ground deformation around a laterally loaded pile and on that laterally loaded pile's response in sand. The active pile head was subjected to lateral loads, and the passive pile was arranged in front of the active pile. In the model tests, the distance between the two pile centers was set to zero (i.e., a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Structural and Construction Engineering (Transactions of AIJ)

سال: 2016

ISSN: 1340-4202,1881-8153

DOI: 10.3130/aijs.81.271