REAL-WORLD EXPERIENCE OF BIOLIMUS A9-ELUTING STENTS AND COMPARISON WITH EVEROLIMUS-ELUTING XIENCE PRIME STENTS IN ALL-COMER REGISTRIES: PRELIMINARY REPORT FOR PATIENT-ORIENTED AND STENT-RELATED 2-YEAR OUTCOMES FROM THE MULTICENTER PROSPECTIVE BIOLIMUS-KOREA-3000 REGISTRY AND EXCELLENT-PRIME REGISTRY
نویسندگان
چکیده
منابع مشابه
Clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents versus durable polymer everolimus-eluting Xience stents
There are limited data about clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents (BP-BES) and durable polymer everolimus-eluting Xience stents (DP-EES) in real world practice. We sought to compare the clinical outcomes of BP-BES and DP-EES in real world cohorts of patients undergoing percutaneous coronary intervention. A prospective multicenter registry enrolled 999 pat...
متن کاملComparison of Everolimus- and Biolimus-Eluting Coronary Stents With€Everolimus-Eluting Bioresorbable Vascular Scaffolds
Fro ini Du an res da Bio (CR Lis Yo Ma BACKGROUND The first CE-approved bioresorbable vascular scaffold (BVS) is effective at treating simple lesions and stable coronary artery disease, but it has yet to be assessed versus the best-in-class drug-eluting stents (DES). OBJECTIVES This study sought to compare the performance of a BVS with that of everolimus-eluting stents (EES) and biolimus-elutin...
متن کاملone-year outcome of everolimus-eluting stents versus biolimus-eluting stents in patients undergoing percutaneous coronary intervention
background: the biolimus-eluting stent (bes), with a biodegradable polymer, has not been previously compared with the everolimus-eluting stent (ees), as a second-generation drug-eluting stent (des).we sought to compare the 1-year outcome between the promus ™ stent (ees type) and the biomatrix ™ stent (bes type). methods: from march 2008 to september 2011, all patients treated with the promus™ s...
متن کاملOne-Year Outcome of Everolimus-Eluting Stents Versus Biolimus-Eluting Stents in Patients Undergoing Percutaneous Coronary Intervention
Background: The biolimus-eluting stent (BES), with a biodegradable polymer, has not been previously compared with the everolimus-eluting stent (EES), as a second-generation drug-eluting stent (DES).We sought to compare the 1-year outcome between the PROMUS™ stent (EES type) and the BioMatrix™ stent (BES type). Methods: From March 2008 to September 2011, all patients treated with the PROMUS™ ste...
متن کاملComparison of everolimus- and biolimus-eluting coronary stents with everolimus-eluting bioresorbable vascular scaffolds: Two-year clinical outcomes of the EVERBIO II trial.
BACKGROUND Data from randomized controlled trials have shown that the ABSORB BVS is non-inferior to Cobalt Chromium everolimus-eluting stents at 2years. METHODS & RESULTS The EVERBIO II trial (Comparison of Everolimus- and Biolimus-Eluting Coronary Stents with Everolimus-Eluting Bioresorbable Vascular Scaffold) is a single-center, assessor-blind, randomized controlled trial enrolling 240 pati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the American College of Cardiology
سال: 2016
ISSN: 0735-1097
DOI: 10.1016/s0735-1097(16)30427-2