Real-time two dimensional dosimetry using Al2O3:C and Al2O3:C,Mg films

نویسندگان

چکیده

The Investigations of this article focus on the response Al2O3:C and Al2O3:C,Mg radioluminescence films for medical dosimetry in various MV photon beams. A system was configured using a scientific camera, attached to head linear accelerator (LINAC), facing beam’s isocenter, where were placed. By appropriate filter lens it is possible measure real time two-dimensional dose-rate distributions. key findings are that present clear advantage compared ones, with no interference from afterglow, better film uniformity, high spatial resolution suitability small field beam dosimetry, while giving overall good Flattening Filter (FF) Free (FFF) modes. results show our can be used planar dose rate assessment manageable correction factors.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-Time Dosimetry for Prostate Brachytherapy Using TRUS and Fluoroscopy

A means of achieving real-time dosimetry for prostate brachytherapy using transrectal ultrasound (TRUS) and fluoroscopy has been developed. The approach is designed to fit into the current protocol used at the Vancouver Cancer Center (VCC) for prostate brachytherapy. The TRUS and fluoroscopic images are fused using a single fluoroscopic image of the TRUS probe. The tip of each needle, used to i...

متن کامل

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

Real-time Scheduling of a Flexible Manufacturing System using a Two-phase Machine Learning Algorithm

The static and analytic scheduling approach is very difficult to follow and is not always applicable in real-time. Most of the scheduling algorithms are designed to be established in offline environment. However, we are challenged with three characteristics in real cases: First, problem data of jobs are not known in advance. Second, most of the shop’s parameters tend to be stochastic. Third, th...

متن کامل

Time-Discontinuous Finite Element Analysis of Two-Dimensional Elastodynamic Problems using Complex Fourier Shape Functions

This paper reformulates a time-discontinuous finite element method (TD-FEM) based on a new class of shape functions, called complex Fourier hereafter, for solving two-dimensional elastodynamic problems. These shape functions, which are derived from their corresponding radial basis functions, have some advantages such as the satisfaction of exponential and trigonometric function fields in comple...

متن کامل

Three dimensional radiation dosimetry using polymer gels

The use of polymer gels to record radiation dose distributions in three dimensions was first proposed in 1992 as a proof-of-principle [1]. The accuracy of these early polymer gel dosimeters and scanning methods was not sufficient for most clinical applications [2]. Since then, several efforts were made to increase the accuracy and precision of both the physical gel dosimeter and the scanning te...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Sensors and Actuators A-physical

سال: 2021

ISSN: ['0924-4247', '1873-3069']

DOI: https://doi.org/10.1016/j.sna.2020.112491