Real-time three-dimensional echocardiography in evaluating Libman-Sacks vegetations
نویسندگان
چکیده
منابع مشابه
Real-time three-dimensional echocardiography in evaluating Libman-Sacks vegetations.
Libman-Sacks endocarditis, characterized by sterile fibrofibrinous vegetations that have the potential to develop anywhere on the endocardial surface, was originally reported in 1924. The mitral valve is most commonly affected, followed by the aortic valve, whereas tricuspid and pulmonary valves are seldom involved. Libman-Sacks vegetations can be found in approximately 1 of 10 patients with sy...
متن کاملMitral valve Libman-Sacks endocarditis visualized by real time three-dimensional transesophageal echocardiography.
Libman-Sacks endocarditis (LSE) is a common manifestation of valve disease in antiphospholipid syndrome. Mitral valve LSE is characterized by verrucous vegetations on the atrial surfaces of valve leaflets. In this report, mitral valve LSE was visualized by real time 3D transesophageal echocardiography (TEE). 3D TEE provides a unique en face view of the mitral valve akin to a surgical or autopsy...
متن کاملLibman-Sacks Endocarditis
In 1924 Libman and Sacks published an account of atypical, sterile, verrucous vegetations on the heart in systemic lupus erythematosus (SLE). [1] Clusters of verrucae, looking like mulberries, were described on the ventricular surface of the posterior leaflet of the mitral valve and found at postmortem. The leaflet and the chordae tendinae are often adherent to the endocardium of the ventricula...
متن کاملReal-time three-dimensional transthoracic echocardiography.
BACKGROUND Complex anatomy of intra-cardiac structures requires spatial orientation of image in three dimensions for better understanding and enhanced image interpretation. We evaluated the feasibility and efficacy of the emerging 'real-time three-dimensional transthoracic echocardiography' technique for comprehensive assessment of cardiac anatomy, physiology, pathomorphology and pathophysiolog...
متن کاملFeasibility study for real time three dimensional Doppler intracardiac echocardiography.
Using catheter-mounted two-dimensional array transducers, we have obtained real-time three-dimensional color flow and spectral Doppler ultrasound images in phantoms. We have constructed several transducers operating at 5 MHz with up to 137 channels inside a 12 French catheter lumen. The transducer configuration may be side scanning or beveled with respect to the long axis of the catheter lumen....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: European Journal of Echocardiography
سال: 2009
ISSN: 1525-2167,1532-2114
DOI: 10.1093/ejechocard/jep172