Fast three-dimensional terahertz computed tomography using real-time line projection of intense terahertz pulse.
We demonstrated fast three-dimensional transmission terahertz computed tomography by using real-time line projection of intense terahertz beam generated by optical rectification in lithium niobate crystal. After emphasizing the advantage of intense terahertz pulse generation for two-dimensional spatio-temporal terahertz imaging, peak-to-peak amplitudes of pulsed terahertz electric field have be...
متن کاملMaterial thickness optimization for transmission-mode terahertz time-domain spectroscopy.
The thickness of a sample material for a transmission-mode terahertz time-domain spectroscopy (THz-TDS) measurement is the subject of interest in this paper. A sample that is too thick or too thin can raise the problem of measurement uncertainty. Although greater thickness allows the terahertz radiation--or T-rays--to interact more with bulk material, the SNR rolls off with thickness due to sig...
متن کاملOn Possibilities of Real-Time Millimeter/Terahertz Three-Dimensional Imaging of Remote Concealed Objects
Z Sk X Usage of MMW/THz imaging systems for remote stealth screening of suspect individuals at entries is of growing interest. Passive imaging systems exploiting only natural MMW/THz emission within observable scene are not quite effective for indoor inspections due to low brightness temperature contrast. The authors have proposed two novel active MMW/THz quasioptical imaging techniques which a...
متن کاملLeft ventricular ejection fraction by real-time three-dimensional echocardiography
Despite a staggering technical progress in echocardiography, in daily clinical practice assessment of left ventricular (LV) ejection fraction (EF) is still often done in a rather inaccurate two-dimensional (2D) manner. Real-time three-dimensional echocardiography (RT3DE) provides a more representative realistic view of LV volumes, thereby being the Necker cube for the naive realism of 2D method...
متن کاملReal-time three-dimensional transthoracic echocardiography.
BACKGROUND Complex anatomy of intra-cardiac structures requires spatial orientation of image in three dimensions for better understanding and enhanced image interpretation. We evaluated the feasibility and efficacy of the emerging 'real-time three-dimensional transthoracic echocardiography' technique for comprehensive assessment of cardiac anatomy, physiology, pathomorphology and pathophysiolog...