A simple neuro-controlle r for a synchronous generator is presented in this paper. The controller performs the function of the terminal voltage control. By representing the proposed neuro-controller in s-domain, its parameters to ensure system stability can be obtained analytically. Results of simulation studies on a non-linear seventh order generator model with the neuro-controller using calcu...
متن کاملAdaptive and Intelligent Systems for Generator Monitoring and Protection Purposes
New adaptive scheme for signal parameter measurement for generator monitoring and protection is presented. The algorithm is based on the orthogonal components of currents and voltages obtained with adaptive orthogonal filters. The filter data window length and coefficients are adapted according to coarsely estimated signal frequency. As a result, the measurements can be performed with high accu...
متن کاملLinearity response characterization of Polystyrene/ Graphene oxide nanocomposite as real-time dosimeter for therapeutic purposes
Introduction: In recent years, one of the emerging two dimensional (2D) carbon based nano- materials namely Graphene Oxide has been incorporated into polymeric matrices to enhance the electrical properties of the composites. The electrical conductivity of Graphene Oxide is excellently used in fabricating polymer-based sensors, energy-related systems, biotechnology, anti-statics...
متن کاملDetermination of Load Angle for Salient-pole Synchronous Machine
This paper presents two methods for load angle determination for salient-pole synchronous generator. The first method uses optical encoder to detect the rotor position. In some cases the end of the rotor shaft is not free to be used and mounting of an encoder is impossible. Therefore, the second method proposes estimation of the load angle based on the measured electrical values that have been ...
متن کاملComparison of an Interior Mounted Permanent Magnet Synchronous Generator with a Synchronous Reluctance Generator for a Wind Application
This article presents a performance comparison of an interior mounted permanent magnet synchronous generator (IPMSG) with a synchronous reluctance generator (SynRG) with the same size for a wind application. It is found that using the same geometrical dimensions, a SynRG can convert 74 % of the power that an IPMSG can convert, while it has 80% of the IPMSG weight. Moreover it is found that the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Energy - Energija
سال: 2020
ISSN: 1849-0751,0013-7448
DOI: 10.37798/202069134