Real-Scale Fire Wind Tunnel Experiment on Generation of Firebrands from a House on Fire
نویسندگان
چکیده
منابع مشابه
wind farm impact on generation adequacy in power systems
در سال های اخیر به دلیل افزایش دمای متوسط کره زمین، بشر به دنبال روش های جایگزین برای تامین توان الکتریکی مورد نیاز خود بوده و همچنین در اکثر نقاط جهان سوزاندن سوخت های فسیلی در نیروگاه های حرارتی به عنوان مهم ترین روش تولید توان الکتریکی مطرح بوده است. به دلیل توجه به مسایل زیست محیطی، استفاده از منابع انرژی تجدید پذیر در سال های اخیر شدت یافته است. نیروگاه های بادی به عنوان یک منبع تولید توان...
15 صفحه اولA New Investigation on Tunnel Pool Fire Phenomenon Using CFD Technique
In this study, the amount of generated pool fire, as a result of the release of chemicals in the case of an accident in tunnels, was simulated and the results were compared to the experimental data. At first, various amounts of spatial resolution (R*) were considered to compare the existing experimental data at different heights at the upstream, downstream and above the pool fire...
متن کاملLessons from a Full Scale Fire Test
This paper draws together some important lessons from a compartment fire test conducted by BRE in the full-scale eight storey steel building at Cardington. The experiment is briefly described, and the main structural observations are highlighted. A numerical structural model of the fire compartment, using the nonlinear analysis program ADAPTIC, is then discussed. The numerical analysis employs ...
متن کاملModelling the Evacuation of People from a Train on Fire in a Railway Tunnel
Fire safety of each structure consists in the creation of conditions for rapid and safe people evacuation, in the limitation of spread of fire and combustion products in the structure and the surroundings of the structure, and in the creation of conditions for rapid, effective and safe response actions of rescue units. In case of fire on a passenger train standing in a tunnel, a top priority ta...
متن کاملKnowledge of Operating Room Staff on Fire Resources and Fire prevention Measurements
Background and Objectives: Fire risk is a potential risk in operating rooms. To have safety, fire risk management and its prerequisites including knowledge enhancement should be considered in operation rooms. The aim of this study was to determine knowledge of operating room staff about fire resources and fire prevention in Valiasr hospital, Boroujen. Material and Methods: In this cross-section...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Fire Science and Technology
سال: 2004
ISSN: 1882-0492,0285-9521
DOI: 10.3210/fst.23.142