Reactions of the hydroperoxide anion with dimethyl methylphosphonate in an ion trap mass spectrometer: evidence for a gas phase α-effect

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A quadrupole ion trap mass spectrometer with three independent ion sources for the study of gas-phase ion/ion reactions.

An instrument for the study of gas-phase ion/ion reactions in which three independent sources of ions, namely, two electrospray ionization sources and one atmospheric sampling glow discharge ionization source, are interfaced to a quadrupole ion trap mass analyzer is described. This instrument expands the scope of gas-phase ion/ion reaction studies by allowing for manipulation of the charge stat...

متن کامل

An electrostatic autoresonant ion trap mass spectrometer.

A new method for ion extraction from an anharmonic electrostatic trap is introduced. Anharmonicity is a common feature of electrostatic traps which can be used for small scale spatial confinement of ions, and this feature is also necessary for autoresonant ion extraction. With the aid of ion trajectory simulations, novel autoresonant trap mass spectrometers (ART-MSs) have been designed based on...

متن کامل

An interface with a linear quadrupole ion guide for an electrospray-ion trap mass spectrometer system.

A new ion sampling interface for an electrospray ionization 3D ion trap mass spectrometer system is described. The interface uses linear rf quadrupoles as ion guides and ion traps to enhance the performance of the 3D trap. Trapping ions in the linear quadrupoles is demonstrated to improve the duty cycle of the system. Dipolar excitation of ions trapped in a linear quadrupole is used to eject un...

متن کامل

Examination of the best pressure range for ion/molecule reactions of anthraquinones in an external source ion trap mass spectrometer.

This study outlines some observations of the pressure effect for gas phase ion-molecule reactions of anthraquinone derivatives with dimethyl ether in an external source ion trap mass spectrometer. At the reagent pressure of 7.998 x 10(-2) Pa, formation of the protonated ions, [M + 13]+, [M + 15]+, and [M + 45]+ ions, of anthraquinones can be observed. However, at the pressure of 1.066 x 10(-2) ...

متن کامل

An ion trap storage/time-of-flight mass spectrometer

An ion trap/time-of-flight (TOF) mass spectrometer combination has been developed in order to combine the storage capabilities of an ion trap with the speed and resolution of a time-of-flight device. The ion trap is an rf quadrupole trap which operates in the total storage mode, i.e., with the dc voltage=0 on the end caps and rf voltage on the ring electrode. The trap has an ion storage time of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Organic & Biomolecular Chemistry

سال: 2008

ISSN: 1477-0520,1477-0539

DOI: 10.1039/b803734e