منابع مشابه
Finite element modeling of a superconducting fault current limiter
This paper summarizes the work done to show finite element modeling results on a high temperature superconductor fault current limiter (FCL). The paper also gives the small mock-up design of the matrix FCL and its finite element model (FEM). It also discusses the limitations of the FEM and explains how the results from the FEM compare with the experimental data derived for the configuration. A ...
متن کاملInfluence of Fault Current Limiter in Voltage Drop and TRV Considering Wind Farm
Influence of distributed generation systems in the distribution systems can increase the level of short-circuit current. The effectiveness of distributed generation systems is affected by the size, location, type of distributed generation systems technology, and the methods of connecting to distribution systems. Wind turbine system is the examples of distributed generation source. Not only does...
متن کاملSeries Resonance Based Fault Current Limiter with Controlling The Point of Common Coupling Voltage
This paper proposes a novel Fault Current Limiter (FCL) for the application on distribution networks to control voltage sags at the Point of Common Coupling (PCC) during faults. This new FCL is based on series resonance including resonance transformer and series capacitor. So, by proper design of the series resonance LC tank, the fault current is limited to an acceptable level. The FCL operatio...
متن کاملSolid State Electronic Fault Current Limiter to Limit the Fault Current in Power System
Increase in power generation capacity of electric power systems has lead to increase in the fault current level which can exceed the maximum designed short-circuit ratings of the switchgear. All the equipment therefore must have a short-circuit rating capable to withstand this level. Short-circuit currents contain extremely high energy and can damage electrical equipment. Typically, the circuit...
متن کاملFault Current Limiter for a Distributed Power System
The up-gradation of an Electrical power generation network results in higher levels of short circuit fault current. Thereby, the existing protection equipment like circuit breakers, isolators and fuses become under capacity and not capable of withstanding higher short circuit currents. Thus the system is highly vulnerable to the adverse effects of short circuits. Replacing the whole protection ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan)
سال: 1991
ISSN: 0389-2441,1880-0408
DOI: 10.2221/jcsj.26.236