Rate-Distortion Theory of Finite Point Processes

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rate-Distortion Theory of Finite Point Processes

We study the compression of data in the case where the useful information is contained in a set rather than a vector, i.e., the ordering of the data points is irrelevant and the number of data points is unknown. Our analysis is based on rate-distortion theory and the theory of finite point processes. We introduce fundamental information-theoretic concepts and quantities for point processes and ...

متن کامل

Simulation of random processes and rate-distortion theory

We study the randomness necessary for the simulation of a random process with given distributions, in terms of the finite-precision resolvability of the process. Finite-precision resolvability is defined as the minimal random-bit rate required by the simulator as a function of the accuracy with which the distributions are replicated. The accuracy is quantified by means of various measures: vari...

متن کامل

Algorithmic Rate-Distortion Theory

We propose and develop rate-distortion theory in the Kolmogorov complexity setting. This gives the ultimate limits of lossy compression of individual data objects, taking all effective regularities of the data into account.

متن کامل

Distortion-Rate Function for Undersampled Gaussian Processes

“THIS PAPER IS ELIGIBLE FOR THE STUDENT PAPER AWARD” We study the fundamental limits in acquisition and transmission of a stationary Gaussian continuoustime process corrupted by noise. The analog signal is digitized into discrete samples with a general analog to digital (A/D) converter that prefilters the continuous process followed by a pointwise sampler. We assume that the sampler, which is n...

متن کامل

Highly accelerated Point-Spread Function mapping based on Finite Rate of Innovation for EPI distortion correction

Institute of Biophysics and Biomedical Engineering, Faculty of Sciences, University of Lisbon, Lisbon, Portugal Hybrid MR-PET scans enable acquisition of both types of images within a session. Despite consistent subject positioning, image alignment can still be challenging. Functional MR images rely on echo-planar imaging (EPI) and present geometric distortions due to static B0 field inhomogene...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Information Theory

سال: 2018

ISSN: 0018-9448,1557-9654

DOI: 10.1109/tit.2018.2829161