Rapid influenza H1N1 diagnostic test: its diagnostic property

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid influenza H1N1 diagnostic test: its diagnostic property

To the editor: The report on assessment of diagnostic properties of rapid influenza H1N1 diagnostic test demonstrated an interesting finding that ‘Rapid tests have high specificity but low sensitivity and thus limited usefulness’. The metaanalysis in this work might have some problems. As different rapid influenza H1N1 diagnostic tests have different basic principles, the use of overall sensiti...

متن کامل

Diagnostic Accuracy of a Rapid Influenza Test for Pandemic Influenza A H1N1

BACKGROUND With the current influenza A H1N1 pandemic (H1N1pdm), it is extremely important that clinicians can quickly and accurately identify influenza cases. METHODOLOGY/PRINCIPAL FINDINGS To investigate the performance of the QuickVue Influenza A+B rapid test, we conducted a prospective study of the diagnostic accuracy of the QuickVue Influenza A+B test compared to real-time reverse transc...

متن کامل

Development and evaluation of a rapid influenza diagnostic test for the pandemic (H1N1) 2009 influenza virus.

We evaluated a new rapid influenza diagnostic test for the pandemic (H1N1) 2009 influenza virus by using real-time reverse transcription-PCR (rRT-PCR) and viral culture. The sensitivities were 68.5% and 64.5%, and the specificities were 98.4% and 97.6%, respectively. This kit should be used with caution, and negative results should be verified by a confirmative test.

متن کامل

Performance of rapid influenza H1N1 diagnostic tests: a meta‐analysis

BACKGROUND Following the outbreaks of 2009 pandemic H1N1 infection, rapid influenza diagnostic tests have been used to detect H1N1 infection. However, no meta-analysis has been undertaken to assess the diagnostic accuracy when this manuscript was drafted. METHODS The literature was systematically searched to identify studies that reported the performance of rapid tests. Random effects meta-an...

متن کامل

Low sensitivity of rapid diagnostic test for influenza.

The QuickVue Influenza A+B Test (Quidel) was used to test nasal swab specimens obtained from persons with influenza-like illness in 3 different populations. Compared with reverse-transcriptase polymerase chain reaction, the test sensitivity was low for all populations (median, 27%; range, 19%-32%), whereas the specificity was high (median, 97%; range, 96%-99.6%).

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Influenza and Other Respiratory Viruses

سال: 2011

ISSN: 1750-2640

DOI: 10.1111/j.1750-2659.2011.00320.x