Rapid EC50 determination of hydrophobic toxicants in continuous droplet biomicrofluidics
نویسندگان
چکیده
منابع مشابه
Rapid and continuous magnetic separation in droplet microfluidic devices.
We present a droplet microfluidic method to extract molecules of interest from a droplet in a rapid and continuous fashion. We accomplish this by first marginalizing functionalized super-paramagnetic beads within the droplet using a magnetic field, and then splitting the droplet into one droplet containing the majority of magnetic beads and one droplet containing the minority fraction. We quant...
متن کاملContinuous Droplet Removal upon Dropwise Condensation of Humid Air on a Hydrophobic Micropatterned Surface
Combination of two physical phenomena, capillary pressure gradient and wettability gradient, allows a simple two-step fabrication process that yields a reliable hydrophobic self-cleaning condenser surface. The surface is fabricated with specific microscopic topography and further treatment with a chemically inert low-surface-energy material. This process does not require growth of nanofeatures ...
متن کاملdetermination of maximal singularity free zones in the workspace of parallel manipulator
due to the limiting workspace of parallel manipulator and regarding to finding the trajectory planning of singularity free at workspace is difficult, so finding a best solution that can develop a technique to determine the singularity-free zones in the workspace of parallel manipulators is highly important. in this thesis a simple and new technique are presented to determine the maximal singula...
15 صفحه اولEditorial: Moving on in biomicrofluidics.
Related Articles Referee Acknowledgment for 2012 AIP Advances 3, 010201 (2013) Editorial: Wedge Causal Manifolds An Unfinished Work of Hans-Jürgen Borchers J. Math. Phys. 53, 120401 (2012) Editorial: Energy and the U.S. Department of State J. Renewable Sustainable Energy 4, 060401 (2012) Editorial: Thank you J. Renewable Sustainable Energy 4, 050401 (2012) Preface to Special Topic: Low-Carbon S...
متن کاملDetermination of Acute Reference Exposure Levels for Airborne Toxicants
Description colorless or yellow liquid Molecular formula HNO3 Molecular weight 63.02 Density 1.50269 g/cm @ 25°C Boiling point 83° C with decomposition Melting point -41.59°C Vapor pressure 62 mm Hg @ 25°C Flashpoint not applicable Explosive limits not applicable Solubility miscible in water Odor threshold 0.27 ppm (AIHA, 1989) Odor description choking odor Metabolites oxides of nitrogen, parti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Micro and Nano Engineering
سال: 2019
ISSN: 2590-0072
DOI: 10.1016/j.mne.2019.05.001