Rapid determination of sulfite ion by using detector tubes
نویسندگان
چکیده
منابع مشابه
Development of An Immobilized Enzyme Electrode for the Determination of Sulfite Ion
An enzyme electrode was developed using the enzyme sulfite oxidase (EC1.8.3.1) immobilized onto pig intestine. Hydrogen peroxide produced was monitored amperometrically. All experimental parameters such as pH, temperature, buffer constituent concentration, were thoroughly investigated and optimized when appropriate. The response to sulfite concentration was linear in the range 5.2´...
متن کاملRapid Determination of Lead in Urine by Ion Exchange.
For routine screening of employees in the lead industry, a method for determination of urinary lead was developed in which this element is removed from urine by means of a chelating agent, eluted, and determined by a modified dithizone method. The method gives values which are about 5% below those obtained by the wet ashing technic, with a precision of ± 2.1% in the range of 2-15 jig. of lead p...
متن کاملRapid Determination of Plasma Ammonia by an Ion-exchange Technic.
A method is described for the colorimetric determination of ammonia in plasma by a batch ion-exchange procedure. The method combines separation of ammonium ion, using a strongly acidic cation-exchange resin, with a sensitive colorimetric procedure which simultaneously elutes and colorimetrically reacts with the ammonium ion to produce a stable color. Interference by basic amino acids is negligi...
متن کاملRapid determination of germanium and tin by ion chromatography
A method was established for the simultaneous determination of germanium and tin in one run by ion chromatography. Using a selected eluent, Ge and Sn were separated on a bifunctional ion-exchange column, followed by a postcolumn chromogenic reaction and spectrophotometric detection at 520 nm. The whole procedure was completed within 5 min with high sensitivity and selectivity at the low-/zg/1 l...
متن کاملRapid determination of urinary total porphyrins by ion exchange chromatography.
Total urinary porphyrins were eluted from a commercially available anion exchange Chromatographie column with hydrochloric acid and determined spectrophotometrically. For 1 ml samples the optimum concentration range for measurement was found to lie between 0.1 and 1.5 mg of total porphyrin/1 urine. Assay of a single sample takes 12 min. The specificity (measurement at three wave lengths), sensi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BUNSEKI KAGAKU
سال: 1981
ISSN: 0525-1931
DOI: 10.2116/bunsekikagaku.30.12_796