Rapid Determination of Sulfite Ion by Potentiometric Argentometric Titration Using Iodide-ion Selective Membrane Electrode
نویسندگان
چکیده
منابع مشابه
Potentiometric Determination of Dopamine Using a Solid-Contact Polymer Membrane Ion-Selective Electrode
Potentiometric Determination of Dopamine Using a Solid-Contact Polymer Membrane Ion-Selective Electrode Tanji Yin1 2 3 ∗ and Wei Qin1 1Key Laboratory of Coastal Zone Environmental Processes, Yantai Institute of Coastal Zone Research YIC , Chinese Academy of Sciences CAS ; Shandong Provincial Key Laboratory of Coastal Zone Environmental Processes, YICCAS, Yantai, Shandong 264003, P. R. China 2So...
متن کاملKinetic potentiometric determination of creatinine in serum with a picrate ion-selective membrane electrode.
We describe a new kinetic method for potentiometric determination of creatinine in serum, based on the creatinine--picrate reaction in alkaline medium (Jaffé reaction). The reaction is monitored with a picrate-selective electrode, and the increase in electrode potential during 270 s is measured and related directly to the creatinine concentration. Small cation-exchange columns are used to separ...
متن کاملPotentiometric titration of sulphate, sulphite and dithionate mixtures, with use of a lead ion-selective electrode.
Simple methods are described for the analysis of sulphate, sulphite and dithionate mixtures by potentiometric titration with lead perchlorate (and use of a lead ion-selective electrode). The error and precision are both about 2-5% for the sulphate concentration range 3 x 10(-3) -6 x 10(-4)M. The sulphur content in fuels derived from refuse was determined by potentiometric titration after bomb-c...
متن کاملSelective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.
A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...
متن کاملDevelopment of An Immobilized Enzyme Electrode for the Determination of Sulfite Ion
An enzyme electrode was developed using the enzyme sulfite oxidase (EC1.8.3.1) immobilized onto pig intestine. Hydrogen peroxide produced was monitored amperometrically. All experimental parameters such as pH, temperature, buffer constituent concentration, were thoroughly investigated and optimized when appropriate. The response to sulfite concentration was linear in the range 5.2´...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: NIPPON KAGAKU KAISHI
سال: 1973
ISSN: 2185-0925,0369-4577
DOI: 10.1246/nikkashi.1973.1473