Rapid catalyst evaluation for Sonogashira coupling in continuous flow
نویسندگان
چکیده
منابع مشابه
Rapid homogeneous-phase Sonogashira coupling reactions using controlled microwave heating.
A microwave-enhanced, rapid and efficient homogeneous-phase version of the Sonogashira reaction is presented. It has been applied to the coupling of aryl iodides, bromides, triflates, and aryl chloride, as well as pyridine and thiophene derivatives with trimethylsilylacetylene. Excellent yields (80-95%) for substrates containing a large variety of substituents in different positions are obtaine...
متن کاملEnhanced catalyst recovery in an aqueous copper-free Sonogashira cross-coupling reaction.
We report the synthesis of a superparamagnetic nanoparticle MNP (γ-Fe(2)O(3)/polymer) supported dendritic catalyst based on a bulky electron-rich phosphine Pd(II) complex. The high reactivity of this catalyst is described in a copper-free Sonogashira C-C cross-coupling reaction in water, and the significant role of surfactant additives is highlighted in the recovery study.
متن کاملMicrowave-assisted Suzuki coupling reactions with an encapsulated palladium catalyst for batch and continuous-flow transformations.
This article describes the design, optimisation and development of a Suzuki cross-coupling protocol mediated by an efficient palladium-encapsulated catalyst (Pd EnCat) under microwave irradiation. The methodology has been used in both batch mode for classical library preparation and in continuous-flow applications furnishing multigram quantities of material. Described is a method that uses dire...
متن کاملHeterogeneous Stille and Sonogashira cross-coupling reactions over palladium anchored mesoporous silica catalyst
A Pd-based heterogeneous catalyst (Pd(II)-MCM-41) derived from post-synthesis modification of mesoporous silica, MCM-41, has been successfully employed in catalytic Stille and Sonogashira cross-coupling reactions. The catalyst affords good yields in all cross-coupling reactions. Notably, the catalyst is capable of activating less reactive chlorobenzene with moderate yield in both the coupling r...
متن کاملNanofluidic devices for rapid continuous-flow bioseparation.
Compared with conventional gel-based techniques, such as gel electrophoresis, which are routinely used for bioseparation in biology and biomedical laboratories, nanofluidic devices with regular engineered sieving structures offer the potential for faster separation, better resolution, higher throughput, and more convenient sample recovery. Here, we detail the fabrication process of a two-dimens...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Arkivoc
سال: 2012
ISSN: 1551-7012