RAPID AND HIGHLY SENSITIVE ENZYME IMMUNOASSAY FOR QUANTITATIVE DETERMINATION OF TETRODOTOXIN
نویسندگان
چکیده
منابع مشابه
Rapid and Sensitive Chemiluminescent Enzyme Immunoassay for the Determination of Neomycin Residues in Milk.
Immunoassays greatly contribute to veterinary drug residue analysis. However, there are few reports on detecting neomycin residues by immunoassay. Here, a rapid and sensitive chemiluminescent enzyme immunoassay (CLIEA) was successfully developed for neomycin residue analysis. CLIEA demonstrated good cross-reactivity for neomycin, and the IC50 value was 2.4 ng/mL in buffer. The average recovery ...
متن کاملRapid and sensitive chemiluminescent enzyme immunoassay for measuring tumor markers.
We developed a chemiluminescent enzyme immunoassay (CLEIA) to quantify such tumor markers as carcinoembryonic antigen (CEA), alpha-fetoprotein (AFP), CA19-9, and CA125. We used a novel chemiluminescent substrate, a derivative of 1,2-dioxetane phosphate (AMPPD), to measure alkaline phosphatase as a labeling enzyme to Fab' fragments of antibody. Regardless of the solid phase, i.e., polystyrene be...
متن کاملA rapid, sensitive enzyme-linked immunoassay for human thyrotropin.
In this enzyme-linked immunoassay for human thyrotropin (TSH) in unextracted serum we use 96-well immunoenzymometric assay plates, first coated with polyclonal antibody to TSH, then incubated with the serum samples and reacted with mouse monoclonal antibody to human TSH. After incubation with alkaline phosphatase-labeled antibody against mouse IgG, disodium p-nitrophenyl phosphate is added and ...
متن کاملluciferase immunoprecipitation system assay, a rapid, simple, quantitative, and highly sensitive antibody detection for parasitic diseases
no abstract
متن کاملDevelopment of a highly sensitive and selective microplate chemiluminescence enzyme immunoassay for the determination of free thyroxine in human serum
A microplate chemiluminescence enzyme immunoassay (CLEIA) with high sensitivity, selectivity and reproducibility was developed for the determination of free thyroxine (FT4) in human serum. A competitive assay has been utilized with horseradish peroxidase (HRP) labeled thyroxine analog in the chemiluminescence (CL) detection. The CL signal produced by the emission of photons from luminol was dir...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Journal of Medical Science and Biology
سال: 1997
ISSN: 0021-5112,1884-2828
DOI: 10.7883/yoken1952.50.133