Rapid analysis of minerals in oysters using microwave decomposition and inductively coupled plasma atomic emission spectrometry
نویسندگان
چکیده
منابع مشابه
Microwave assisted digestion coupled with inductively coupled plasma optical emission spectrometry for determining element concentrations in halophytes
Introduction: This study was carried out to determine elements (Li, Na, K, Mg, Ca, Ba, B, Al, Si, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Ag and P) in the Suaeda vermiculata (S. vermiculata) and Suaeda aegyptiaca (S. aegyptiaca) in three different regions of Southern Iran using inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave-assisted acid digestion. Materials and ...
متن کاملSelective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry
In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...
متن کاملMarine Sediment Analysis Using Inductively Coupled Plasma Optical Emission Spectrometry
Inductively coupled plasma optical emission spectrometry was applied to the determination of trace impurities in tantalum powder. The matrix effects of tantalum in the determination of trace level impurities such as Cr, Fe, Nb, Ni, and Ti were studied by measuring the intensities of each trace element in solution at various concentrations of tantalum. As the concentration of the interfering ele...
متن کاملInductively Coupled Plasma - Optical Emission Spectrometry
ACKNOWLEDGEMENTS INTRODUCTION CONTENTS 1.1 Forensic Science Investigations 1.2 Forensic Science Analysis 2 1.3 Inductively Coupled Plasma-Optical Emission Spectrometry 7 1.4 The Aims of This Investigation 8 2 INDUCTIVELY COUPLED PLASMA-OPTICAL EMISSION SPECTROMETRY 10 2 .l Introduction 2.2 The Inductively Coupled Plasma 2.3 Instrumentation Used in This Study 2.3.1 Radio Frequency Generator 2.3....
متن کاملScreening and Optimization of Microextraction of Pb(II) by Inductively Coupled Plasma-Atomic Emission Using Response Surface Methodology
Dispersive liquid–liquid microextraction (DLLME) combined with inductively coupled plasma-atomic emission spectrometry (ICP-AES) was applied for the determination of lead in different environmental water samples. Ammonium pyrrolidine dithiocarbamate (APDC), chloroform and ethanol were used as chelating agent, extraction solvent and disperser solvent, respectively. The effective parameters, such...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Aquaculture Reports
سال: 2021
ISSN: 2352-5134
DOI: 10.1016/j.aqrep.2021.100585