Ramp-Rate Sensitivity of SSC Dipole Magnet Prototypes.
نویسندگان
چکیده
منابع مشابه
Automated Methods of Field Harmonic Signal Extraction and Processing for the Magnets in Superconducting Supercollider
A versatile ®eld measurement system HAL2 was developed and used for SSC magnet measurements. The system based on V/F converter and 32 bit counters are set on a VME /modi®ed VME bus. The system was capable of measuring the high ramp rate harmonics which was a vital issue especially for the construction of SSC High Energy Booster. System description and the implementation techniques for high ramp...
متن کاملMagnetic Field Fluctuations in Sc Dipole Magnet
Magnetic field fluctuations at the betatron frequency can lead to emittance growth in circular accelerators. Tolerances are extremely tight for large hadron colliders like LHC and VLHC[1]. We performed experimental studies of the fluctuations in a stand-alone superconducting Tevatron magnet. Here we give a general description of the experimental set-up, present main results and discuss conseque...
متن کاملMeasurement of Ramp Rate Sensitivity in Model Dipoles With Ebanol-Coated Cable
Ramp rate sensitivity in superconducting dipole magnets has been shown to vary in an unpredictable fashion between magnets constructed using similar fabrication techniques. Test results from a series of model magnets are presented, one of which was constructed using ebanolcoated strands. The ramp rate sensitivity and ac loss observed is described.
متن کاملMagnetic Field Measurement of the Air Slot Dipole Magnet
Field measurement results of the air slot type dipole magnet are presented. The vacant portion, called the air slot, located in the iron core controls the flow of the magnetic flux and improves uniformity of the magnetic field. This magnet realizes a better magnetic field distribution over a wide range of field strengths. The prototype of the magnet had been fabricated and tested to verify the ...
متن کاملEffect of Induced Dipole-Induced Dipole Potential and the Size of Colliding Particles on Ion-Quadrupolar Molecule Collision Rate Constants
Classical trajectory (Monte Carlo) calculation is used to calculate collision rate constants of ion-quadrupolar molecule interactions for the H¯+C2H2 system. The method presented here takes into account the effect of the induced dipole-induced dipole potential on ion-quadrupolar molecule collision rate constants. It is also assumed that the colliding particles have a d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan)
سال: 1994
ISSN: 0389-2441,1880-0408
DOI: 10.2221/jcsj.29.424