Radon Measurement Standards and Calibration
This issue of the Journal of Research of the National Institute of Standards and Technology resulted from a one-half day seminar devoted to descriptions of the current status of the metrology of radon in international laboratories specializing in that area. The seminar, held June 5, 1989, at the Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, Federal Republic of Germany was co-sponso...
متن کاملCalibration and Standards in Flow Measurement
Calibration is defined as follows: ‘The set of operations that establish, under specified conditions, the relationship between values of quantities indicated by a measuring instrument or measuring system and the corresponding values realized by standards.’ It is important to recognize at the outset the definition of a ‘calibration’ and to note that the ‘comparison’ applies only to the condition...
متن کاملRadon monitor calibration using NIST radon emanation standards: steady flow method.
The National Institute of Standards and Technology (NIST) polyethylene-encapsulated 226Ra/222Rn emanation (PERE) standards (old SRM 4968 and new SRMs 4971, 4972, and 4973) provide precise radon emanation rate, certified to a high degree of accuracy (approximately to 2%). Two new SRM 4973 standards containing totally 1036 Bq (0.028 microCi) of 226Ra, emanate 0.114 Bq (3.08 pCi) of 222Rn per min....
متن کاملICARE Radon Calibration Device
An aerodynamic calibration device called ICARE is briefly described. ICARE is currently being used at the Nuclear Research Center of Saclay in France for the certification of instruments employed in measurement of artificial radioactive particulate airborne contamination. ICARE is essentially a blower. Aerosols calibrated in size and labelled with 137Cs or 239Pu are injected in the mainstream o...
متن کاملCalibration of Electret-Based Integral Radon Monitors Using NIST Polyethylene-Encapsulated 226Ra/222Rn Emanation (PERE) Standards
The recently developed 222Rn emanation standards that are based on polyethylene-encapsulated 226Ra solutions were employed for a first field-measurement application test to demonstrate their efficacy in calibrating passive integral radon monitors. The performance of the capsules was evaluated with respect to the calibration needs of electret ionization chambers (E-PERM®, Rad Elec Inc.). The enc...