Radiopharmaceutical Production for PET Imaging in Poland
نویسندگان
چکیده
منابع مشابه
Manual production and quality control of 68Ga-PSMA-11 radiopharmaceutical for PET-CT imaging of prostate cancer: optimization and 60 production series experience
Background: 68Ga-PSMA-11, a novel PET radiopharmaceutical, is currently used for imaging of almost all prostate cancers. However, automatic radiolabeling procedures have been recommended. In this research, according to the chemical nature of the PSMA-11, manual, optimized and safe production of this radiopharmaceutical has been investigated and a standard method has been presented to achieve a ...
متن کاملGallium‐68 DOTATATE Production with Automated PET Radiopharmaceutical Synthesis System: A Three Year Experience
Objective(s): Gallium‐68 (Ga‐68) is an ideal research and hospital‐based PET radioisotope. Currently, the main form of Ga‐68 radiopharmaceutical that is being synthesised in‐house is Ga‐68 conjugated with DOTA based derivatives. The development of automated synthesis systems has increased the reliability, reproducibility and safety of radiopharmaceutical productions. Here we report on our three...
متن کاملCyclotron production of 43Sc for PET imaging
BACKGROUND Recently, significant interest in (44)Sc as a tracer for positron emission tomography (PET) imaging has been observed. Unfortunately, the co-emission by (44)Sc of high-energy γ rays (E γ = 1157, 1499 keV) causes a dangerous increase of the radiation dose to the patients and clinical staff. However, it is possible to produce another radionuclide of scandium-(43)Sc-having properties si...
متن کاملProduction and quality control of 82mRb and primary PET scans using its radiopharmaceutical for heart examinations [Persian]
According to the importance of positron emitters in nuclear medicine, 82mRb was produced as a member of this group of radiopharmaceuticals. After being converted into an injectable form, enough information was provided for imaging with this radiopharmaceutical. 82mRb with high radioisotopic purity and half-life of 6.5 hours, in chloride form, can be considered as a suitable positron emitt...
متن کاملA Generator-Produced Gallium-68 Radiopharmaceutical for PET Imaging of Myocardial Perfusion
Lipophilic cationic technetium-99m-complexes are widely used for myocardial perfusion imaging (MPI). However, inherent uncertainties in the supply chain of molybdenum-99, the parent isotope required for manufacturing 99Mo/99mTc generators, intensifies the need for discovery of novel MPI agents incorporating alternative radionuclides. Recently, germanium/gallium (Ge/Ga) generators capable of pro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Physica Polonica A
سال: 2015
ISSN: 0587-4246,1898-794X
DOI: 10.12693/aphyspola.127.1520