Radiometric Evaluation of SNPP VIIRS Band M11 via Sub-Kilometer Intercomparison with Aqua MODIS Band 7 over Snowy Scenes
نویسندگان
چکیده
منابع مشابه
Radiometric performance assessment of Suomi NPP VIIRS SWIR Band (2.25 μm)
Suomi NPP VIIRS SWIR band M11 (2.25 μm) has larger radiometric uncertainty compared to the rest of the reflective solar bands. This is due to a number of reasons including prelaunch calibration uncertainties. One of the most commonly used technique to verify the radiometric stability and accuracy of VIIRS is by intercomparing it with other well calibrated radiometers such as MODIS. However one ...
متن کاملA Multi-band statistical restoration of the Aqua MODIS 1.6 micron band
Currently, the MODIS instrument on the Aqua satellite has a number of broken detectors resulting in unreliable data for 1.6 micron band (band 6) measurements. Damaged detectors, transmission errors, and electrical failure are all vexing but seemingly unavoidable problems leading to line drop and data loss. Standard interpolation can often provide an acceptable solution if the loss is sparse. In...
متن کاملEvaluation of VIIRS and MODIS Thermal Emissive Band Calibration Stability Using Ground Target
The S-NPP Visible Infrared Imaging Radiometer Suite (VIIRS) instrument, a polar orbiting Earth remote sensing instrument built using a strong MODIS background, employs a similarly designed on-board calibrating source—a V-grooved blackbody for the Thermal Emissive Bands (TEB). The central wavelengths of most VIIRS TEBs are very close to those of MODIS with the exception of the 10.7 μm channel. T...
متن کاملMonitoring the NOAA Operational VIIRS RSB and DNB Calibration Stability Using Monthly and Semi-Monthly Deep Convective Clouds Time Series
The Visible and Infrared Imaging Radiometer Suite (VIIRS) onboard the Joint Polar Satellite System (JPSS)/Suomi National Polar-Orbiting Partnership (SNPP) satellite provide sensor data records for the retrievals of many environment data records. It is critical to monitor the VIIRS long-term calibration stability to ensure quality EDR retrieval. This study investigates the radiometric calibratio...
متن کاملCrosstalk Effect in SNPP VIIRS
An investigation has been carried out to examine the crosstalk contamination in the Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the Suomi National Polar-orbiting Partnership (SNPP) spacecraft. Prior to this study, the cause of the pronounced striping in Earth View (EV) images and obvious discontinuity in the EV brightness temperature (BT) of the thermal emissive bands (TEB) during...