Radioisotope Laboratory Techniques
نویسندگان
چکیده
منابع مشابه
Chronic cyanide exposure: a clinical, radioisotope, and laboratory study.
The effect of chronic cyanide exposure in the electroplating sections of three factories employing 36 workers was studied and compared with a control group. The concentration of cyanides to which the workers were exposed was measured. The regression line showing the relationship between thiocyanates in urine and the concentration of cyanides in the air was plotted. Increased percentages of haem...
متن کاملRadioisotope Renography
hgs. 144. 72s.) Lonidon: Baidiirc, 1Tindall & Cox, 1963. Dit. \xivlter speaks wvitlh authority onl thiis relatively new mietlhodi of inivestigationi, as he hlas t)een conicernled in its developmenlt from almost the be(ginning. lie gives a clear accounlt of the technique, dealinig xvith equipmenit, choice of radioactive test agent, anld interpretationi of renograms. He has included maniy example...
متن کاملRadioisotope Powered Cardiac Pacemakers.
Over 100,000 implantable cardiac pacemakers are currently being used to rehabilitate patients with heart block. The chemical batteries powering these pacemakers usually fail within a few years. A variety of nuclear batteries with the potential of providing long-lived (10-20 years) pacemaker power, are under development. This paper reviews the status of this development. Nuclear powered pacemake...
متن کاملPromotion of radioisotope excretion.
Nuclear medicine would be greatly aided if compounds were available to promote the excretion of unwanted radioisotopes from biological systems. Such preparations would make possible greater use of long-lived radionuclides in medicine and would reduce some of the environmental hazards associated with nuclear energy. The biochemistry of radioisotope excretion is complicated because there are so m...
متن کاملAssessment of left ventricular performance and myocardial viability using quantitative radioisotope techniques.
The diagnostic value of a combined radionuclide technique was compared with conventional angiocardiographic techniques in 60 patients with coronary artery disease. Quantitative 201Tl myocardial imaging combined with radionuclide angiocardiography using 99mTc-HSA provided a safe and accurate method for the assessment of left ventricular performance. The defects on the 201Tl images correlated wit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Clinical Pathology
سال: 1959
ISSN: 0021-9746
DOI: 10.1136/jcp.12.4.389-b