منابع مشابه
Radiographic evaluation of calcaneal fractures;
Objective The aim of this study was to correlate the functional outcome after treatment for displaced intra-articular calcaneal fracture with plain radiography. Design Prognostic study of a retrospective cohort with concurrent follow-up. Patients A total of 33 patients with a unilateral calcaneal fracture and a minimum follow-up of 13 months participated. Patients filled in three disease-specif...
متن کاملACR Appropriateness Criteria ® 3 Rib Fractures RIB FRACTURES
ACR Appropriateness Criteria 1 Rib Fractures American College of Radiology ACR Appropriateness Criteria Clinical Condition: Rib Fractures Variant 1: Adult. Suspected rib fractures from minor blunt trauma (injury confined to ribs). Radiologic Procedure Rating Comments RRL* X-ray chest 8 Obtain PA view. ☢ X-ray rib views 5 ☢ ☢ ☢ CT chest without IV contrast 3 ☢ ☢ ☢ Tc-99m bone scan whole body 2 ☢...
متن کاملEssential radiographic evaluation for distal radius fractures.
Fractures of the distal radius can be complex injuries, often generating multiple fragments with distortion of the normal anatomy in all three dimensions. Superficial assessment of the injury on the standard PA and lateral radiographs often can result in incomplete recognition of the injury pattern and a misdirected approach to treatment. In addition, failure to recognize subtle radiographic fi...
متن کاملRib fracture: Different radiographic projections
BACKGROUND Rib fracture is the most common thoracic injury. It is thought to be present in 10% of all traumatic injuries and in almost 40% of patients who sustained severe non-penetrating trauma. There are 12 pairs of ribs. This study reviews various methods of acquisition and reconstruction of radiographic images of traumatic rib fractures in order to determine the optimal views and to simplif...
متن کاملEvaluation of intramedullary rib splints for less-invasive stabilisation of rib fractures.
BACKGROUND Intramedullary fixation of rib fractures with generic Kirschner wires has been practiced for over 50 years. However, this technique has not been advanced to address reported complications of wire migration and cut-out. This biomechanical study evaluated a novel rib splint designed to replicate the less-invasive fixation approach of Kirschner wires while mitigating their associated co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: American Journal of Roentgenology
سال: 1982
ISSN: 0361-803X,1546-3141
DOI: 10.2214/ajr.138.1.91