Radiochromic Films for the Two-Dimensional Dose Distribution Assessment
نویسندگان
چکیده
Radiochromic films are mainly used for two-dimensional dose verification in photon, electron, and proton therapy treatments. Moreover, the radiochromic film types available today allow their use a wide range, corresponding to applications from low-medical diagnostics high-dose beam profile measurements charged particle medical accelerators. An in-depth knowledge of characteristics films, operating principles, reading techniques is paramount importance exploit all features this interesting versatile radiation detection system. This short review focuses on these main aspects by considering most recent works subject.
منابع مشابه
Role of in vivo dosimetry with radiochromic films for dose verification during cutaneous radiation therapy
PURPOSE To evaluate the role of in vivo dosimetry with radiochromic films for dose verification in cutaneous radiation therapy (RT). METHODS Five patients with 8 cutaneous or sub-cutaneous malignancies of the face, neck, trunk and extremity receiving RT were included. Orthovoltage, megavoltage photon therapies were applied based on anatomic location. The delivered dose for each target was mea...
متن کاملDose Distribution Evaluation and Independent Quality Check of Spherical INTRABEAM™ Applicators via Radiochromic EBT2 Film Measurement
Introduction: The present study was conducted to implement a simple practical independent quality check of depth dose and isotropy of the Intrabeam™ therapeutic X-ray machine using radiochromic EBT2 film. Material and Methods: Theindependent quality check of 1.5, 3.5, and 5-cm spherical Intrabeam™ applicators was accomplished using particular EBT2 film cutting pieces with internal rounded edge...
متن کاملA new method for ideal dose distribution of two adjacent fields for external beam radiation therapy
Abstract Background: Adjacent treatment fields are commonly used in external beam radiation therapy, such as mantle and inverted-Y fields for the treatment of Hodgkin’s disease and craniospinal fields used in the treatment of medulloblastoma and head and neck tumors when the lateral neck fields are placed adjacent to the anterior supraclavicular field. In each of these situations, there is a p...
متن کاملThe Verification of iPlan Commissioning by Radiochromic EBT2 Films
Purpose: To evaluate the measured dose distributions using radiochromic EBT2 films for small fields in iPlan (BrainLab) commissioning. Methods: Radiochromic EBT2 films were irradiated with 6 MV photons on a Varian Trilogy linac using polystyrene phantoms. The measurements included dose profiles and depth doses for field sizes of 1 × 1, 2 × 2, 3 × 3, 4 × 4, and 10 × 10 cm etc. The dose profile m...
متن کاملHigh sensitivity radiochromic film dose comparisons.
This short note investigates the dose characteristics of a relatively new high sensitivity radiochromic film (Gafchromic HS) and compares dose and energy response to various Gafchromic film types and radiographic (EDR-2) film. The original MD-55-1 and two improved sensitivity films, MD-55-2 and HS film, were investigated for energy and dose response. Results show that the energy response of the...
متن کاملذخیره در منابع من