Radiochromic film spectroscopy of laser-accelerated proton beams using the FLUKA code and dosimetry traceable to primary standards

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reference dosimetry using radiochromic film

The objectives of this study are to identify and quantify factors that influence radiochromic film dose response and to determine whether such films are suitable for reference dosimetry. The influence of several parameters that may introduce systematic dose errors when performing reference dose measurements were investigated. The effect of the film storage temperature was determined by comparin...

متن کامل

Radiochromic Film Dosimetry

Published by the American Association of Physicists in Medicine DISCLAIMER: This publication is based on sources and information believed to be reliable, but the AAPM and the editors disclaim any warranty or liability based on or relating to the contents of this publication. The AAPM does not endorse any products, manufacturers, or suppliers. Nothing in this publication should be interpreted as...

متن کامل

Annular shaped laser-accelerated proton beams

Since their discovery in 1999 [1] the topic of laseraccelerated ions has attracted high attention both in the field of plasma-physics and in the accelerator community. In a typical laser-accelerated ion scheme a thin metal foil is irradiated by an ultra-intense chirped pulse amplified laser beam which leads to the generation of relativistic electrons. These electrons are accelerated through the...

متن کامل

3-D reconstruction of a laser accelerated proton beam using micro-structured target foils and radiochromic film detectors∗

The generation of high-current multi-MeV protons by irradiating thin foils with short-pulse, ultrahigh intensity lasers (τ < ps, Iλ >10 8 W/cm μm) has gained great attention in the field of laser-ion acceleration due to remarkable properties of the accelerated beam and its suitability for a new type of ion source. The acceleration process takes place on the nonirradiated rear side of the foil. ...

متن کامل

Dosimetry of blood irradiation with radiochromic film.

It has been shown that radiochromic film is an ideal dosimeter for assessment and verification of delivered dose to irradiated blood products. Using a parallel opposing two-field technique on a medical linear accelerator, blood is irradiated to diminish the risk of transfusion-associated graft vs. host disease (TA-GVHD). The blood products are irradiated in a Perspex blood box to an applied dos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Laser and Particle Beams

سال: 2011

ISSN: 0263-0346,1469-803X

DOI: 10.1017/s0263034611000206