Abstract Objectives To review radiation exposure during emergency ureteric stent insertion to identify differences based on operator experience, specialty and stone characteristics. Patients methods A retrospective audit over 10 years was performed for patients who underwent urolithiasis with intraoperative fluoroscopy. Outcomes measured included (mGy), dose area product (Gy/cm 2 ), fluoroscopy time, characteristics patient BMI. Analysis in IBM SPSS Version 28. p < 0.05 considered statistically significant. Results Four hundred ten were identified, a median age of 57 years, 64.6% male BMI 30. Urolithiasis left‐sided 50.8%, size 7 mm predominantly proximal (49%) followed by mid (34.5%) distal (12.1%) location. Median 12.6 mGy, 2.94 Gy/cm time 44.5 s, no significant difference between consultants registrars. No association subgroups location, gender, size, laterality or registrar (general surgery vs. urology). Conclusion identified registrars subspecialty We suggest formal safety education all health professionals involved intra‐operative personal dosimeters.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ureteric stenting in kidney transplants.

The routine use of ureteric stents after a kidney transplant for prophylactic measures is debatable. Concerns have been raised regarding the potential complications and costs of routine stenting. Here, we review the literature based on studies in favor of and against the routine placement of ureteric stents in kidney transplant patients. Some studies have shown a benefit to patients who have ro...

متن کامل

Perioperative radiation exposure in a pregnant woman

The perioperative imaging of a pregnant woman presents a unique challenge to orthopaedics surgeon as concern about the radiation risk to the embryo or fetus. This article highlights effect of radiation exposure on foetus.I would like to discuss about the amount of radiation exposure in a pregnant woman during fluoroscopic guided closed femoral Interlock nailing as radiation has significant...

متن کامل

Carotid stenting: is there an operator effect? A pooled analysis from the carotid stenting trialists' collaboration.

BACKGROUND AND PURPOSE Randomized clinical trials show higher 30-day risk of stroke or death after carotid artery stenting compared with surgery. We examined whether operator experience is associated with 30-day risk of stroke or death in the Carotid Stenting Trialists' Collaboration database. METHODS The Carotid Stenting Trialists' Collaboration is a pooled individual patient database includ...

متن کامل

Urological complications in ureteric stenting live related renal transplantation.

OBJECTIVE To determine the frequency and types of post-transplant urological complications in live-related kidney transplantation with reference to the impact of JJ ureteric stent. STUDY DESIGN Case series. PLACE AND DURATION OF STUDY Shaikh Zayed Postgraduate Medical Institute and National Institute of Kidney Diseases, Lahore, from June 2006 to July 2010. METHODOLOGY Consecutive renal tr...

متن کامل

Operator radiation exposure during percutaneous transluminal coronary angioplasty.

Operator radiation exposure during percutaneous transluminal coronary angioplasty as compared with that during routine coronary angiography is unknown. Therefore, cumulative radiation exposure at operator eye level was measured in two physicians (operators 1 and 2) during performance of coronary angioplasty and routine coronary angiography. The physicians participated together during angioplast...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: BJUI compass

سال: 2023

ISSN: ['2688-4526']

DOI: https://doi.org/10.1002/bco2.245