Radiation dose reduction in pediatric CT-guided musculoskeletal procedures
نویسندگان
چکیده
منابع مشابه
Radiation dose reduction with hybrid iterative reconstruction for pediatric CT.
PURPOSE To assess image quality and radiation dose reduction with hybrid iterative reconstruction of pediatric chest and abdominal computed tomographic (CT) data compared with conventional filtered back projection (FBP). MATERIALS AND METHODS A total of 234 patients (median age, 12 years; age range, 6 weeks to 18 years) underwent chest and abdominal CT in this institutional review board-appro...
متن کاملCT dose reduction in pediatric patients.
CT is an incredibly valuable imaging tool, but there are unique concerns with pediatric patients, including the increase of sensitivity to radiation, increase risk of cancer formation with the longer life expectancy, and larger radiation doses received when adult CT settings are used. With a grant from the AHRA and Toshiba Putting Patients First program, Memorial Hermann Healthcare System was a...
متن کاملRadiation Dose Reduction in Paranasal Sinus CT
Objectives. To (1) compare the radiation dose of low-dose computed tomography (CT) to that of standard-dose CT, (2) determine the minimum optimal radiation dose for use in patients who need endoscopic sinus surgery, and (3) assess the reliability of iterative model reconstruction. Study Design. Prospective single-institution study. Setting. Tertiary care center. Subjects and Methods. We recruit...
متن کاملReducing patient radiation dose during CT-guided procedures: demonstration in spinal injections for pain.
BACKGROUND AND PURPOSE CT guidance may improve precision for diagnostic and therapeutic spinal injections, but it can increase patient radiation dose. This study examined the impact of reducing tube current on patient radiation exposure and the technical success for these procedures, by using axial acquisitions for short scan lengths and eliminating nonessential imaging. MATERIALS AND METHODS...
متن کاملNonlinear filtering for CT radiation dose reduction
Nonlinear bilateral filters (BF) deliver a fine blend of computational simplicity and blurfree denoising. However, little is known about their nature, noise-suppressing properties, and optimal choices of filter parameters. Our study is meant to fill this gap—explaining the underlying mechanism of bilateral filtering and providing the methodology for optimal filter selection. Practical applicati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Pediatric Radiology
سال: 2013
ISSN: 0301-0449,1432-1998
DOI: 10.1007/s00247-013-2691-4