Radiating Slot in the Coaxial Cable Shield: Measurement Based Characterization

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two-slot coiled coaxial cable resonator: reaching critical coupling at a reduced number of coils.

This paper reports the experimental demonstration of a coiled coaxial cable resonator capable of meeting the critical coupling condition using a reduced number of coils relative to previously reported coiled resonators. By introducing a second slot along the length of the device, a two-slot coiled coaxial cable resonator was fabricated and critical coupling observed at 22 turns. An additional d...

متن کامل

An Off-Center “Coaxial” Cable

A “coaxial” transmission line has inner conductor of radius a and outer conductor of radius b, but the axes of these two cylinders are offset by a small distance δ ¿ b. Deduce the capacitance and inductance per unit length, and the impedance Z, accurate to order δ/b. The (relative) dielectric constant and permeability of the medium between the two conductors both unity. The relevant frequencies...

متن کامل

“Hidden” Momentum in a Coaxial Cable

Calculate the electromagnetic momentum and identify the “hidden” mechanical momentum in a coaxial cable of length L, inner radius a, outer radius b, when a battery of voltage V is connected to one end and a load resistor R0 is connected to the other. The current may be taken as uniformly distributed over the inner conductor, which has resistivity ρ. The outer conductor has negligible resistivit...

متن کامل

Computer simulation and temperature measurement for MR hyperthermia therapy using coaxial-slot antenna

Introduction Hyperthermia therapy is commonly used for tumor treatment that already has been widely investigated. The principle of hyperthermia therapy employs the clear difference in heat sensitivity of normal cells and tumor cells at 42°C to 43°C and above. This difference is used for selective killing of only the tumor cells. Recently, hyperthermia therapy combined with magnetic resonance im...

متن کامل

Radiation from the Open End of a Coaxial Cable

(1) and c is the speed of light in vacuum. Estimate the time-average power P (i.e., the radiation) that escapes from the end of the cable using vector (or scalar) Huygens-Kirchhoff diffraction theory for the case that the cable is excited with a TEM wave with λ b. Compare the cases of a coaxial cable by itself, and one with its outer conductor attached to a ground plane such that the radiation ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Communications Software and Systems

سال: 2015

ISSN: 1846-6079,1845-6421

DOI: 10.24138/jcomss.v11i3.102