Quinary excitation method for pulse compression ultrasound measurements

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quinary excitation method for pulse compression ultrasound measurements.

A novel switched excitation method for linear frequency modulated excitation of ultrasonic transducers in pulse compression systems is presented that is simple to realise, yet provides reduced signal sidelobes at the output of the matched filter compared to bipolar pseudo-chirp excitation. Pulse compression signal sidelobes are reduced through the use of simple amplitude tapering at the beginni...

متن کامل

Pulse compression and traveling wave excitation scheme

A single dispersive element is shown to be sufficient for simultaneous pulse compression and tilting of the pulse front, and therefore well-suited for traveling-wave excitation of targets. It is shown that in all the previous arrangements used for traveling wave excitation, spatially dependent group velocity dispersion occurs along the target. A compensated arrangement is proposed that provides...

متن کامل

Improved scatterer size estimation using backscatter coefficient measurements with coded excitation and pulse compression.

Scatterer size estimates from ultrasonic backscatter coefficient measurements have been used to differentiate diseased tissue from normal. A low echo signal-to-noise ratio (eSNR) leads to increased bias and variance in scatterer size estimates. One way to improve the eSNR is to use coded excitation (CE). The normalized backscatter coefficient was measured from three tissue-mimicking phantoms by...

متن کامل

Pulse Compression Method for Radar Signal Processing

One fundamental issue in designing a good radar system is it’s capability to resolve two small targets that are located at long range with very small separation between them. Pulse compression techniques are used in radar systems to avail the benefits of large range detection capability of long duration pulse and high range resolution capability of short duration pulse. In these techniques a lo...

متن کامل

Small Lesion Detection with Resolution Enhancement Compression: a Method of Coded Excitation/pulse Compression by Paul Mitchell Linden

A novel coded excitation method, resolution enhancement compression (REC), increases the axial resolution and the echo signal-to-noise ratio (eSNR) for an ultrasonic imaging system. The REC technique was examined for its ability to improve lesion detectability. In addition to lesion detectability, the REC technique was examined in the context of being peak voltage limited or peak pressure limit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Ultrasonics

سال: 2008

ISSN: 0041-624X

DOI: 10.1016/j.ultras.2007.10.001