Query regarding rate of complications with Implantable Collamer Lens

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

outcomes and complications of implantable collamer lens and toric implantable collamer lens for the correction of high myopia with and without astigmatism

purpose: to evaluate the efficacy, safety, predictability and stability of implantable collamer lens (icl) and toric icl for the treat­ment of high myopia and high myopic astigmatism, one year prospective study. methods: in this prospective nonrandomized clinical trial, 95 eyes of 51 patients that had icl (31 eyes) and toric icl (64 eyes) were participate in eye research center, department of o...

متن کامل

outcomes and complications of implantable collamer lens and toric implantable collamer lens for the correction of high myopia with and without astigmatism (one year prospective study)

purpose : to evaluate the efficacy, safety, predictability and stability of implantable collamer lens (icl) and toric icl for the treat­ment of high myopia and high myopic astigmatism methods : in this prospective nonrandomized clinical trial, 95 eyes of 51 patients who underwent icl (31 eyes) and toric icl (64 eyes) implantations were participate in eye research center, department of ophthalmo...

متن کامل

More Than a Decade of Experience With Implantable Collamer Lens.

We read with great interest the article by Moya et al. in the August 2015 issue.1 The literature on longterm outcomes and complications of posterior chamber phakic intraocular lenses is scarce and the authors effectively describe their 12-year experience with implantable collamer lens (ICL) implantation. We reviewed 349 eyes of 216 patients, of which 155 (44.4%) were treated with spheric ICLs a...

متن کامل

Spontaneous Rotation of a Toric Implantable Collamer Lens

We present a case of toric implantable collamer lens (TICL) spontaneous rotation in a patient with myopic astigmatism. A 23-year-old female underwent TICL implantation. Preoperative uncorrected visual acuity (UCVA) was 20/800 and 20/1200, respectively, with -7.75 -4.25 × 0° and -8.25 -5.25 × 180°. The left eye achieved an UCVA of 20/30. After 3 months of successful implantation of TICL in the l...

متن کامل

Buffering zone of implantable Collamer lens sizing in V4c

BACKGROUND The purpose of this study was to identify factors related to the unexpected vault in V4c implantable collamer lens (ICL; STAAR Surgical) implantation. METHODS V4c ICLs were implanted in 43 eyes of 43 patients for the correction of myopia. The implanted V4c ICL sizes were determined individually with our previous V4 ICL sizing nomogram based on the sulcus-to-sulcus diameter (STS), a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Current Ophthalmology

سال: 2019

ISSN: 2452-2325

DOI: 10.1016/j.joco.2018.10.002