Quasiparticle Generation-Recombination Noise in the Limit of Low Detector Volume
نویسندگان
چکیده
We have measured the quasiparticle generation-recombination (GR) noise in aluminium lumped element kinetic inductors with a wide range of detector volumes at various temperatures. The basic consists meandering inductor and interdigitated capacitor fingers. volume is varied from 2 to 153 $\mu \mathrm{m}^{3}$ by changing width length maintain constant inductance. started measuring power spectrum density (PSD) detectors frequency which function GR we clearly observed roll off 10 kHz corresponds lifetime. Using data temperature sweep resonator convert fluctuation observe its strong dependence on volume: smaller display less amplitude. Meanwhile saturated low all as life time notation="LaTeX">$\boldsymbol{\tau _{qp}}$ approaches value temperature.
منابع مشابه
The Low Noise Limit in Gene Expression
Protein noise measurements are increasingly used to elucidate biophysical parameters. Unfortunately noise analyses are often at odds with directly measured parameters. Here we show that these inconsistencies arise from two problematic analytical choices: (i) the assumption that protein translation rate is invariant for different proteins of different abundances, which has inadvertently led to (...
متن کاملthe effect of task cognitive complexity and time limit on the performance of the learners with different proficiency levels in second language writing skill
this study investigated the effects of manipulating the cognitive complexity of tasks along +/- few elements and the time limits on l2 learners writing performance. to conduct the study, 60 iranian efl learners with two levels of proficiency, low and high intermediate, were selected and assigned to three groups based on the time devoted to task completion. the participants performed both a simp...
15 صفحه اولLow-noise PPLN-based single-photon detector
This paper describes the detection of single photons, which have been transmitted through standard fiber at the telecom wavelength of 1310 nm. Following transmission, the 1310-nm photon is up-converted to 710 nm in a periodical-poled LiNbO3 (PPLN) waveguide and then detected by a silicon-based avalanche photodiode (Si-APD). The overall detection efficiency of the detector is 20%. We have also c...
متن کاملthe effect of the record infancy in crimilly acts of guilties (in karaj city)
چکیده یکی از مهمترین دغدغه های بزرگ جوامع بشری، از دیر باز تا کنون که ذهن پژوهشگران و متخصصان بهداشت روانی و اجتماعی و دولتها رابه خود مشغول داشته، مسأله ی بزهکاری می باشد. شناخت کامل پدیده ی بزهکاری و بزهکار، علل وعوامل سقوط یک انسان، چگونگی درمان وی و درنهایت پیشگیری ازبزهکاری ودریک کلام سالم سازی یک جامعه، رسالت عظیم، انسانی ومقدسی می باشد که با بررسی شخصیت مجرم یعنی[ انسانی که تحت شرای...