Quantitative thermal measurement by the use of scanning thermal microscope and resistive thermal probes
نویسندگان
چکیده
منابع مشابه
suppression of coke formation in thermal cracking by coke inhibitors
the main purpose of this research was to:1.develop a coking model for thermal cracking of naphtha.2.study coke inhibition methods using different coke inhibitors.developing a coking model in naphtha cracking reactors requires a suitable model of the thermal cracking reactor based on a reliable kinetic model.to obtain reliable results all these models shall be solved simultaneously.for this pu...
15 صفحه اولThe near-field scanning thermal microscope.
We report on the design, characterization, and performance of a near-field scanning thermal microscope capable to detect thermal heat currents mediated by evanescent thermal electromagnetic fields close to the surface of a sample. The instrument operates in ultrahigh vacuum and retains its scanning tunneling microscope functionality, so that its miniature, micropipette-based thermocouple sensor...
متن کاملMicro-thermal analysis: scanning thermal microscopy and localised thermal analysis.
Micro-thermal analysis combines the imaging capabilities of atomic force microscopy with the ability to characterise, with high spatial resolution, the thermal behaviour of materials. The conventional AFM tip is replaced by a miniature heater/thermometer which enables a surface to be visualised according to its response to the input of heat (in addition to measuring its topography). Areas of in...
متن کاملConfocal thermal-lens microscope.
The use of a confocal detection scheme in a dual-beam thermal-lens microscope is presented. The scheme allows the measurement of absorption factors down to 1.2 x 10(-7) in a 0.35-microm3 volume by use of a heating laser power of 100 mW incident upon the sample. Results are presented that prove that a 450-nm axial resolution is possible when a 1.2 water immersion objective lens with a N.A. of 1....
متن کاملThermoreflectance based thermal microscope
Thermal images of active semiconductor devices are acquired and processed in real time using visible light thermoreflectance imaging with 34 mK sensitivity. By using a 16316 alternating current coupled photodiode array with synchronous frequency domain filtering a dynamic range of 123 dB is achieved for 1 s averaging. Thus with a stable and higher power light source, fundamentally the camera ca...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Applied Physics
سال: 2020
ISSN: 0021-8979,1089-7550
DOI: 10.1063/1.5125062