منابع مشابه

Effects of steep Trendelenburg position and pneumoperitoneum on middleear pressure in patients undergoing robotic radical prostatectomy.

BACKGROUND/AIM The aim of this study was to quantify the changes in middle ear pressure (MEP) during robot-assisted radical prostatectomy (RARP). MATERIALS AND METHODS Thirty patients undergoing RARP were included in this study. MEP was obtained at the following time points: awake (T1), postintubation (T2), pneumoperitoneum + 1 h of Trendelenburg position (T3), pneumoperitoneum + 2 h of Trend...

متن کامل

Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study

Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...

متن کامل

Post-operative alopecia after robotic surgery in steep Trendelenburg position: a restated observation of pressure alopecia.

Postoperative alopecia is an uncommon complication and its outcome is aesthetically drastic. Although its mechanism has not been clearly elucidated, a proposed risk factor is steep Trendelenburg positioning (30-40 degrees) that is frequently used during robotic gynecologic surgeries. We report a case of postoperative alopecia in 53-year-old female patient who had undergone robotic-assisted lapa...

متن کامل

A Comparative Assessment of Intraocular Pressure in Prolonged Steep Trendelenburg Position Versus Level Supine Position Intervention

Background: The purpose was to evaluate a level supine intervention (LSI) during laparoscopic surgery in steep Trendelenburg position (Lap ST). Increased intraocular pressure (IOP) and decreases in ocular perfusion pressure have been monitored during Lap ST procedures. Peri-orbital swelling and venous congestion in addition to IOP may produce a low perfusion state in the eye, via a compartment ...

متن کامل

Changes in intraocular pressure and optic nerve sheath diameter in patients undergoing robotic-assisted laparoscopic prostatectomy in steep 45° Trendelenburg position

BACKGROUND To evaluate changes in intraocular pressure (IOP) and intracerebral pressure (ICP) reflected by the optic nerve sheath diameter (ONSD) in patients undergoing robotic-assisted laparoscopic prostatectomy (RALP) in permanent 45° steep Trendelenburg position (STP). METHODS Fifty-one patients undergoing RALP under a standardised anaesthesia. IOP was perioperatively measured in awake pat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Anaesthesiology Clinical Pharmacology

سال: 2020

ISSN: 0970-9185

DOI: 10.4103/joacp.joacp_96_20