Quantitative Proton Spectroscopy of the Testes at 3 T
نویسندگان
چکیده
منابع مشابه
Comparison of Real-Time Water Proton Spectroscopy and Echo-Planar Imaging Sensitivity to the BOLD Effect at 3 T and at 7 T
Gradient-echo echo-planar imaging (GE EPI) is the most commonly used approach to assess localized blood oxygen level dependent (BOLD) signal changes in real-time. Alternatively, real-time spin-echo single-voxel spectroscopy (SE SVS) has recently been introduced for spatially specific BOLD neurofeedback at 3 T and at 7 T. However, currently it is not known how neurofeedback based on real-time SE...
متن کاملProton and phosphorus magnetic resonance spectroscopy of the healthy human breast at 7 T
In vivo water- and fat-suppressed 1 H magnetic resonance spectroscopy (MRS) and 31 P magnetic resonance adiabatic multi-echo spectroscopic imaging were performed at 7 T in duplicate in healthy fibroglandular breast tissue of a group of eight volunteers. The transverse relaxation times of 31 P metabolites were determined, and the reproducibility of 1 H and 31 P MRS was investigated. The transver...
متن کاملDifferentiation of glioblastoma multiforme from metastatic brain tumor using proton magnetic resonance spectroscopy, diffusion and perfusion metrics at 3 T
PURPOSE To assess the contribution of (1)H-magnetic resonance spectroscopy (1H-MRS), diffusion-weighted imaging (DWI), diffusion tensor imaging (DTI) and dynamic susceptibility contrast-enhanced (DSCE) imaging metrics in the differentiation of glioblastomas from solitary metastasis, and particularly to clarify the controversial reports regarding the hypothesis that there should be a significant...
متن کاملProton T (1) and T (2) relaxation times of human brain metabolites at 3 Tesla.
Longitudinal and transverse relaxation times were measured for proton MRS signals from human brain metabolites at 3 T using a short-echo STEAM protocol and a surface coil as a transmitter/receiver. Volumes of interest containing mostly grey or mostly white matter were selected in occipital lobes of healthy subjects and relaxation times for the following resonances were obtained: N-acetylasparta...
متن کاملProton MR spectroscopy in mild cognitive impairment and Alzheimer disease: comparison of 1.5 and 3 T.
BACKGROUND AND PURPOSE Theoretically, proton ((1)H) MR spectroscopy at a higher field strength has the advantages of higher signal-to-noise ratio and improved spectral resolution. We therefore compared the ability of single-voxel (1)H MR spectroscopy at 1.5 and 3 T to diagnostically discriminate among cognitively normal elderly subjects, patients with mild cognitive impairment (MCI), and patien...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Investigative Radiology
سال: 2018
ISSN: 1536-0210,0020-9996
DOI: 10.1097/rli.0000000000000414