Quantitative magnetization transfer ultrashort echo time imaging of the Achilles tendon
نویسندگان
چکیده
منابع مشابه
Quantitative magnetization transfer ultrashort echo time imaging of the Achilles tendon.
Ultrashort echo time imaging allows the short T(2) Achilles tendon to be directly visualized with MRI. Radiofrequency saturation 1 kHz or less off-resonance has been used previously to improve image contrast. In this study, magnetization transfer was investigated in the Achilles tendon of eight normal volunteers and one patient with psoriatic arthritis. 2D Ultrashort echo time images were acqui...
متن کاملUltrashort echo time magnetization transfer (UTE-MT) imaging of cortical bone.
Magnetization transfer (MT) imaging is one way to indirectly assess pools of protons with fast transverse relaxation. However, conventional MT imaging sequences are not applicable to short T2 tissues such as cortical bone. Ultrashort echo time (UTE) sequences with TE values as low as 8 µs can detect signals from different water components in cortical bone. In this study we aim to evaluate two-d...
متن کاملUltrashort echo imaging of cyclically loaded rabbit patellar tendon.
Tendinopathy affects individuals who perform repetitive joint motion. Magnetic resonance imaging (MRI) is frequently used to qualitatively assess tendon health, but quantitative evaluation of inherent MRI properties of loaded tendon has been limited. This study evaluated the effect of cyclic loading on T₂* values of fresh and frozen rabbit patellar tendons using ultra short echo (UTE) MRI. Eigh...
متن کاملPulsed magnetization transfer spin-echo MR imaging.
Cross relaxation between macromolecular protons and water protons is known to be important in biologic tissue. In magnetic resonance (MR) imaging sequences, selective saturation of the characteristically short T2 macromolecular proton pool can produce contrast called magnetization transfer contrast, based on the cross-relaxation process. Selective saturation can be achieved with continuous wave...
متن کاملSimultaneous Echo Refocused Magnetization Transfer Imaging
Purpose: To increase the efficiency of densely encoded magnetization transfer imaging of the brain, we time-multiplex multiple slices within the same readout using simultaneous echo refocusing FLASH imaging with magnetization transfer (MT) preparation (MT-SER-FLASH). Materials and Methods: Inefficiency in total scan time results from the number of frequency samples needed for sufficient quality...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Magnetic Resonance in Medicine
سال: 2011
ISSN: 0740-3194
DOI: 10.1002/mrm.22715