Quantitative Fluorometric Assay for Rapid Enzymatic Characterization ofBifidobacterium longumand Related Bifidobacteria

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enzymatic fluorometric assay for myo-inositol trisphosphate.

The determination of myo-inositol trisphosphate by an enzymatic fluorometric assay is presented. The method involves the acid extraction of water-soluble inositol polyphosphates followed by separation by anion-exchange chromatography. Samples are subsequently neutralized by passage over a Dowex Cl- resin and elution with lithium chloride. Samples are then desalted with ethanol. Following dephos...

متن کامل

Rapid fluorometric assay for plasma warfarin.

As in all fluorometric procedures, glassware, reagents, and specimens must be kept free of fluorescent contamination. Glassware must be cleaned with an inorganic detergent and rinsed with distilled water. Paraflim should be used to seal tubes for mixing procedures. Ten milliliters of venous blood was collected into tubes containing 0.1 ml. sodium citrate (38 gm./100 ml. water), or 20 mg. ethyle...

متن کامل

A rapid, automated enzymatic fluorometric assay for determination of D-arabinitol in serum.

A rapid enzymatic fluorometric assay for measuring D-arabinitol in serum was developed using recombinant D-arabinitol dehydrogenase from Candida albicans (rArDH). rArDH was produced in Escherichia coli and purified by dye-ligand affinity chromatography. rArDH was highly specific for D-arabinitol, cross-reacting only with xylitol (4.9%) among all polyols tested. A Cobas Fara II centrifugal autoa...

متن کامل

Quantitative Bacterial Micro-Assay for Rapid Diagnosis of Galactosemia: Application in Galactosemia Neonatal Screening

In the present study a new economic and rapid bacterial micro-assay for simultaneous detection and quantitative measurement of serum galactose was developed. Analysis of the standard curve showed a linearity range for galactose from 2 mg/dL to 180 mg/dL with a regression equation of Y = 0.013X ? 0.083; R² = 0.962. The advantage of the method is its ability to measure serum galactose quantitativ...

متن کامل

Fluorometric assay for alcohol sulfotransferase.

A sensitive fluorometric assay was developed for alcohol sulfotransferase (AST). This was the first continuous fluorometric assay reported for AST. It used 3'-phosphoadenosine 5'-phosphosulfate regenerated from 3-phosphoadenosine 5'-phosphate by a recombinant phenol sulfotransferase (PST) using 4-methylumbelliferyl sulfate as the sulfuryl group donor. The recombinant PST did not use the alcohol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Microbiology and Immunology

سال: 1991

ISSN: 0385-5600

DOI: 10.1111/j.1348-0421.1991.tb01626.x