Quantitative determination of a Mesalazine using reversed phase high- performance liquid chromatography (RP-HPLC)

نویسندگان

چکیده

Mesalazine was quantified in a fast, accurate and sensitive way using reversed-phase high-performance liquid chromatography (RP-HPLC) method. In this method, separation column of porous silica particles L10 (300 × 4.6mm) used, the flow rate is 0.8 ml/min, temperature 25 °C, reagent wavelength 230 nm, injection volume 20 μl. As for mobile phase, it consisted acetonitrile 10% 0.1 phisphoric acid 0.1% 90% water pH 4. The method validated by calculating recovery that ranged between (95.0457-102.280%), correlation coefficient (0.9991) linearity (20-160 μg/ml).The successfully applied quantitative determination mentioned drug.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination and Validation of Eflornithine Hydrochloride by (Rp-Hplc) Reversed Phase High Performance Liquid Chromatography

A simple highly sensitive, rapid, precise, accurate and specific RP-HPLC method was developed for quantification of eflornithine hydrochloride (2-difluoromethyl-DL-ornithine; DFMO) in its commercial formulation. In this RP-HPLC method, the separation was performed using BDS Hypersil 5μ C18 (150 X 4.6 mm) column at room temperature by using methanol: 2% of Glacial acetic acid in water (80:20 v/v...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

A Reversed Phase High Performance Liquid Chromatographic Method for Determination of Rapamycin

Easily degradating and various isomeric forms of rapamycin (Sirolimus) face the determination of this compound to many challenges. In this study, we developed and validated the isocratic reversed phase high performance liquid chromatographic (RP-HPLC) method for rapamycin. Separation was performed on a C8 column (MZ, 15 × 4.6 mm, 5 µm particle size) using methanol:water (80:20 v/v) as the mobil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Health Sciences (IJHS)

سال: 2022

ISSN: ['2550-6978', '2550-696X']

DOI: https://doi.org/10.53730/ijhs.v6ns4.12076