Quantitative comparison of contrast and imaging depth of ultrahigh-resolution optical coherence tomography images in 800–1700 nm wavelength region
نویسندگان
چکیده
منابع مشابه
Quantitative comparison of contrast and imaging depth of ultrahigh-resolution optical coherence tomography images in 800–1700 nm wavelength region
We investigated the wavelength dependence of imaging depth and clearness of structure in ultrahigh-resolution optical coherence tomography over a wide wavelength range. We quantitatively compared the optical properties of samples using supercontinuum sources at five wavelengths, 800 nm, 1060 nm, 1300 nm, 1550 nm, and 1700 nm, with the same system architecture. For samples of industrially used h...
متن کاملOptimal wavelength for ultrahigh-resolution optical coherence tomography.
The influence of depth dependent dispersion by the main component of biological tissues, water, on the resolution of OCT was studied. Investigations showed that it was possible to eliminate the influence of depth dependent dispersion by water in tissue by choosing a light source with a center wavelength near 1.0 microm. Ultrahigh resolution ophthalmic imaging was performed at this wavelength ra...
متن کاملUltrahigh-resolution optical coherence tomography.
In the past two decades, optical coherence tomography (OCT) has been established as an adjunct diagnostic technique for noninvasive, high-resolution, cross-sectional imaging in a variety of medical fields. The rapid development of ultrabroad bandwidth light sources has recently enabled a significant improvement in OCT imaging resolution, demonstrating the potential of OCT to accomplish its orig...
متن کاملIn vivo ultrahigh-resolution optical coherence tomography.
Ultrahigh-resolution optical coherence tomography (OCT) by use of state of the art broad-bandwidth femtosecond laser technology is demonstrated and applied to in vivo subcellular imaging. Imaging is performed with a Kerr-lens mode-locked Ti:sapphire laser with double-chirped mirrors that emits sub-two-cycle pulses with bandwidths of up to 350 nm, centered at 800 nm. Longitudinal resolutions of ...
متن کاملHigh-speed, high-resolution Fourier-domain optical coherence tomography system for retinal imaging in the 1060 nm wavelength region.
A high-speed (47,000 A-scans/s), ultrahigh axial resolution Fourier domain optical coherence tomography (OCT) system for retinal imaging at approximately 1060 nm, based on a 1024 pixel linear array, 47 kHz readout rate InGaAs camera is presented. When interfaced with a custom superluminescent diode (lambda(c) = 1020 nm, Deltalambda = 108 nm, Pout = 9 mW), the system provides 3.3 microm axial OC...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Biomedical Optics Express
سال: 2012