Quantitative chemical exchange sensitive MRI using irradiation with toggling inversion preparation
نویسندگان
چکیده
منابع مشابه
Quantitative chemical exchange sensitive MRI using irradiation with toggling inversion preparation.
Chemical exchange (CE) sensitive MRI contrast acquired with an off-resonance irradiation pulse is affected by other relaxation mechanisms, such as longitudinal and transverse relaxations. In particular, for intermediate CEs, the effect of transverse relaxation often dominates CE contrast. Since water relaxation rates can change significantly in many pathological conditions or during physiologic...
متن کاملQuantitative mapping of chemical compositions with MRI using compressed sensing.
In this work, a magnetic resonance (MR) imaging method for accelerating the acquisition time of two dimensional concentration maps of different chemical species in mixtures by the use of compressed sensing (CS) is presented. Whilst 2D-concentration maps with a high spatial resolution are prohibitively time-consuming to acquire using full k-space sampling techniques, CS enables the reconstructio...
متن کاملFast multislice pH-weighted chemical exchange saturation transfer (CEST) MRI with Unevenly segmented RF irradiation.
Chemical exchange saturation transfer (CEST) MRI is a versatile imaging technique for measuring microenvironment properties via dilute CEST labile groups. Conventionally, CEST MRI is implemented with a long radiofrequency irradiation module, followed by fast image acquisition to obtain the steady state CEST contrast. Nevertheless, the sensitivity, scan time, and spatial coverage of the conventi...
متن کاملPhase sensitive inversion recovery with simultaneous dark fat rendering by virtual chemical inversion
Background On delayed-enhancement (DE-CMR), both fat and infarcted myocardium appear bright making them difficult to differentiate. Standard chemical shift fat-suppression (FatSatCS) consists of a fat-frequency selective saturation followed by readout. This approach is suboptimal in clinical DE-CMR sequences which typically have long readout times (100-200ms) and as a result, fat magnetization ...
متن کاملRapid and Quantitative MRI of Chemical Exchange and Magnetization Transfer. by TEJAS
.................................................................................................... 7
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Magnetic Resonance in Medicine
سال: 2012
ISSN: 0740-3194
DOI: 10.1002/mrm.24449