QUANTITATION OF HUMAN PROTHROMBIN BY RADIOIMMUNO-ASSAY (RIA)

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Activation of Human Prothrombin by Human Prothrombinase

The kinetics of the activation of human prothrombin catalyzed by human prothrombinase was studied using the fluorescent a-thrombin inhibitor dansylarginineN-(3-ethyl-1,5-pentanediyl)amide(DAPA). Prothrombinase proteolytically activates prothrombin to athrombin by cleavages at Arg273-Thr274 (bond A) and Arg322-Ile323 (bond B). The differential fluorescence properties of DAPA complexed with the...

متن کامل

Control of oral anticoagulant treatment by chromogenic prothrombin assay.

Doses of oral anticoagulants in 50 patients on long term treatment were easily and satisfactorily monitored over six months by an automated chromogenic assay of prothrombin (CPA). It is suggested that chromogenic assay of one or more of the vitamin K dependent coagulation factors would provide a readily standardised alternative to those conventional tests which depend on human brain derived rea...

متن کامل

Macropinosome quantitation assay

In contrast to phagocytosis, macropinocytosis is not directly initiated by interactions between cell surface receptors and cargo ligands, but is a result of constitutive membrane ruffling driven by dynamic remodelling of cortical actin cytoskeleton in response to stimulation of growth factor receptors. Wang et al. (2010) [13] developed a reliable assay that allows quantitative assessment of the...

متن کامل

Human C-peptide Quantitation by LC-MS Isotope-Dilution Assay in Serum or Urine Samples

Introduction C-peptide is a 31-amino acid central part of the pro-insulin molecule. Equal amounts of insulin and C-peptide are released from cleavage of proinsulin by specific beta cell endopeptidases within the pancreatic islets of Langerhans. The exact biological role of C-peptide is not completely understood. C-peptide has generally been considered a byproduct of insulin biosynthesis, but re...

متن کامل

Human apolipoprotein C-II quantitation by sandwich enzyme-linked immunosorbent assay.

A specific, sensitive and accurate, non competitive enzyme-linked immunosorbent assay was developed for the quantitation of human apolipoprotein C-II. Using apolipoprotein C-II and apolipoprotein C-III immunosorbent columns, monospecific anti-apolipoprotein C-II antibodies were prepared for coating and for the preparation of a peroxidase-antibody conjugate. The assay is sensitive down to 0.25 n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Pediatric Research

سال: 1977

ISSN: 0031-3998,1530-0447

DOI: 10.1203/00006450-197704000-00631