Quantifying X-Ray Fluorescence Data Using MAPS
نویسندگان
چکیده
منابع مشابه
X-ray Absorption Spectroscopy Using X–ray Fluorescence Spectrometer
Strong characteristic Kα X-ray lines are accompanied by weak lines due to the radiative Auger effect (RAE) [1, 2]. The characteristic Kα fluorescent X-rays (K-L2,3 lines) are emitted by the 2p→1s electric dipole transition after one of the 1s electron photoionization, Though the probability is less than 0.01, one of the 2p electrons is excited into an unoccupied discrete or continuum level simu...
متن کاملQuantifying Mesoscale Neuroanatomy Using X-Ray Microtomography
Methods for resolving the three-dimensional (3D) microstructure of the brain typically start by thinly slicing and staining the brain, followed by imaging numerous individual sections with visible light photons or electrons. In contrast, X-rays can be used to image thick samples, providing a rapid approach for producing large 3D brain maps without sectioning. Here we demonstrate the use of sync...
متن کاملDetermining the Content of Silicon Dioxide in Bauxites Using X-Ray Fluorescence Spectrometry
The X-ray fluorescence spectrometry and the MA.BM.006 reference spectrophotometric methods were used to determine the content of SiO2 (%) in bauxites from different deposits. The treatment of samples prior to the analysis involved the following steps: annealing, melting using the borax method, and the formation of beads. Certified reference bauxite samples were used for the cali...
متن کاملQuantifying instrument errors in macromolecular X-ray data sets.
An indicator which is calculated after the data reduction of a test data set may be used to estimate the (systematic) instrument error at a macromolecular X-ray source. The numerical value of the indicator is the highest signal-to-noise [I/sigma(I)] value that the experimental setup can produce and its reciprocal is related to the lower limit of the merging R factor. In the context of this stud...
متن کاملInvestigation and Measurement of Ash Content of Coal in Zirab Coal Mine-Iran Using Dual Energy -Ray and X-Ray Fluorescence Methods
Coal with low ash content has an important role in the coal and steel industry. There are different methods to measure the ash content. The conventional method which is used in most coal mines of Iran, is to burn the coal and measure the remaining ash. A new method has been recently developed at Nuclear Research Center (NRC) of Iran, Which works on the basis of the absorption of the dual en...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Visualized Experiments
سال: 2018
ISSN: 1940-087X
DOI: 10.3791/56042