Quantifying ventilation change due to radiation therapy using 4DCT Jacobian calculations
نویسندگان
چکیده
منابع مشابه
Reducing radiation dose and enhancing imaging quality of 4DCT for radiation therapy using iterative reconstruction algorithms
Purpose Four-dimensional computed tomography (CT) images are typically used to quantify the necessary internal target volumes for thoracic and abdominal tumors. However, 4-dimensional CT is typically associated with excessive imaging dose to patients and the situation is exacerbated when using repeat 4-dimensional CT imaging on a weekly or daily basis throughout fractionated therapy. The aim of...
متن کاملDirect EIT Jacobian calculations for conductivity change and electrode movement.
Electrical impedance tomography (EIT) is very sensitive to deformations of the medium boundary shape. For lung imaging, breathing and changes in posture move the electrodes and change the chest shape, resulting in image artefacts. Several approaches have been proposed to improve the reconstructed images; most methods reconstruct both the boundary deformation and conductivity change from the mea...
متن کاملVentilation Series Similarity: A Study for Ventilation Calculation Using Deformable Image Registration and 4DCT to Avoid Motion Artifacts
The major problem with ventilation distribution calculations using DIR and 4DCT is the motion artifacts in 4DCT. Quite often not all phases would exhibit mushroom motion artifacts. If the ventilation series similarity is sufficiently robust, the ventilation distribution can be calculated using only the artifact-free phases. This study investigated the ventilation similarity among the data deriv...
متن کاملAssessment of secondary neutron dose due to dental restorations in head and neck radiation therapy
Introduction: One of scientific concern is increasing of unwanted neutron dose to the patient, in head and neck radiation therapy due to the presence of some isotopes in dental restorations and head of medical linac. The aim of this study is to measure the equivalent dose of thermal and fast neutron due to head of Siemens Primus Linac and a healthy tooth, Amalgam, Ni-Cr alloy a...
متن کاملA Microdosimetry model of kidney for nephrotoxicity due to internal radiation therapy
Introduction: We describe a nephron-based dosimetry model for renal toxicity for radiopharmaceutical therapy suited to the nonuniform activity distribution of radiopharmaceutical. In radiopharmaceutical therapy, renal toxicity is observed while whole-kidney and renal cortex absorbed dose values are below toxicity thresholds established by external beam and targeted radiope ptid...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medical Physics
سال: 2018
ISSN: 0094-2405
DOI: 10.1002/mp.13105