Quantification of vanadium in serum by electrothermal atomic absorption spectrometry.

We describe an ultrasensitive and reliable method for determining vanadium in human serum by electrothermal atomic absorption spectrometry. After lyophilization, the serum is digested in acid at high pressure, and the digests are evaporated to a small volume. Vanadium in the digests is complexed with cupferron, extracted, and dried. The residue is redissolved in formic acid, where it is 15-fold...

متن کامل

Improved determination of vanadium in biological fluids by electrothermal atomic absorption spectrometry.

We made sensitive and accurate electrothermal atomic absorption spectrometric measurements of vanadium in small volumes of serum. The wet-digested sample was extracted into an organic solvent, with N-benzoyl-N-(o-tolyl)hydroxylamine (BTA) as the chelating reagent. After evaporating the solvent, we dissolved the residue in acetic acid, and injected a 60-microL aliquot into a graphite furnace. In...

متن کامل

Determination of vanadium in human hair slurries by electrothermal atomic absorption spectrometry.

This work describes an analytical procedure for vanadium determination in human hair slurries by electrothermal AAS using longitudinal heating (LHGA) and transversal heating (THGA) graphite furnace atomizers. The samples were powdered using cryogenic grinding and the hair slurries containing 0.2% (m/v) were prepared in three different media for determination of vanadium: 0.14molL(-1) HNO(3), 0....

متن کامل

Determination of cadmium in wine by electrothermal atomic absorption spectrometry.

A method is described for direct electrothermal atomic absorption spectrometric (ETAAS) determination of cadmium in untreated samples of wine. Pyrolytic graphite tubes and graphite tubes with standard L'vov pyrolytic platforms were tested as atomizers. The detection limit achieved was 0.08 microg L(-1) Cd in wine. The relative standard deviation for the concentration range from 0.2 to 10 microg...