Quantification of liver fat in mice: comparing dual-echo Dixon imaging, chemical shift imaging, and 1H-MR spectroscopy
نویسندگان
چکیده
منابع مشابه
Quantification of liver fat in mice: comparing dual-echo Dixon imaging, chemical shift imaging, and 1H-MR spectroscopy.
We evaluated dual-echo Dixon in-phase and out-of-phase (IP-OP), chemical shift imaging (CSI), and (1)H MRS (hydrogen MR spectroscopy) in estimating fat content (FC) in phantoms and in livers of mice. Phantoms were made according to the volume percentage of fat ranging from 0% to 100%. The three MR methods were performed to measure FC in phantoms and in livers of obese leptin-deficient (ob/ob), ...
متن کاملProton MR Spectroscopy in Fatty Liver: Single Volume Spectroscopy versus Chemical Shift Imaging
Proton MR Spectroscopy has been applied to the evaluation of fatty liver , but few comparisons has been made between different clinical spectroscopic techniques. Using similar parameters for spectral acquisition and consistent positioning of the volume of interest (VOI) , we compared the semiquantitative data of methylene(-CH2) groups of trilycerides of rat fatty liver obtained by SE sequence ,...
متن کاملHigh SNR Acquisitions Improve the Repeatability of Liver Fat Quantification Using Confounder-corrected Chemical Shift-encoded MR Imaging
PURPOSE To determine whether high signal-to-noise ratio (SNR) acquisitions improve the repeatability of liver proton density fat fraction (PDFF) measurements using confounder-corrected chemical shift-encoded magnetic resonance (MR) imaging (CSE-MRI). MATERIALS AND METHODS Eleven fat-water phantoms were scanned with 8 different protocols with varying SNR. After repositioning the phantoms, the ...
متن کاملFast gradient-echo chemical-shift imaging.
A fast chemical-shift imaging using the gradient-echo technique is proposed for the separation of the water and fat in human in vivo imaging. This technique also incorporates magnetic field inhomogeneity correction in the fast chemical-shift imaging. Experimental results of the proposed imaging technique demonstrate that the method would be useful for quick in vivo water-fat separation imaging ...
متن کاملLow-grade glioma: correlation of short echo time 1H-MR spectroscopy with 23Na MR imaging.
BACKGROUND AND PURPOSE There is considerable variability in the clinical behavior and treatment response of low-grade (WHO grade II) gliomas. The purpose of this work was to characterize the metabolic profile of low-grade gliomas by using short echo time (1)H-MR spectroscopy and to correlate metabolite levels with MR imaging-measured sodium ((23)Na) signal intensity. Based on previous studies, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Lipid Research
سال: 2011
ISSN: 0022-2275
DOI: 10.1194/jlr.d016691