Quality control tests of the front-end optical link components for the ATLAS Liquid Argon Calorimeter Phase-1 upgrade

نویسندگان

چکیده

We present the procedures and results of quality control tests for front-end optical link components in ATLAS Liquid Argon Calorimeter Phase-1 upgrade. The include a Vertical-Cavity Surface-Emitting Laser (VCSEL) driver ASIC LOCld, custom transmitter/transceiver modules MTx/MTRx, transmitter LOCx2. MTx, LOCx2 each contain two channels with same structure, while MTRx has channel receiver channel. Each is tested at 5.12 Gbps. A total 5341 LOCld chips, 3275 MTx modules, 797 3198 chips are qualified. yields 73.9%, 98.0%, 98.4%, 61.9% LOCx2, MTRx, respectively.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quality Control of Optical Transmitters for the ATLAS Liquid Argon Calorimeter

A quality control test is performed on nearly 2000 custom optical transmitters for use in the Liquid Argon Calorimeter of the ATLAS detector. More than 90% of these optical transmitters passed the test and have been installed in the calorimeter readout system. The acceptance criteria, measurement procedure, and results of the quality control test are presented in this note.

متن کامل

control of the optical properties of nanoparticles by laser fields

در این پایان نامه، درهمتنیدگی بین یک سیستم نقطه کوانتومی دوگانه(مولکول نقطه کوانتومی) و میدان مورد مطالعه قرار گرفته است. از آنتروپی ون نیومن به عنوان ابزاری برای بررسی درهمتنیدگی بین اتم و میدان استفاده شده و تاثیر پارامترهای مختلف، نظیر تونل زنی(که توسط تغییر ولتاژ ایجاد می شود)، شدت میدان و نسبت دو گسیل خودبخودی بر رفتار درجه درهمتنیدگی سیستم بررسی شده اشت.با تغییر هر یک از این پارامترها، در...

15 صفحه اول

A high speed serializer ASIC for ATLAS Liquid Argon calorimeter upgrade

We have been developing a serializer application-specific integrated circuit (ASIC) based on a commercial 0.25-μm silicon-on-sapphire (SOS) CMOS technology for the ATLAS liquid argon calorimeter front-end electronics upgrade. The first prototype, a 5 Gbps 16:1 serializer has been designed, fabricated, and tested in lab environment and in 200 MeV proton beam. The test results indicate that the f...

متن کامل

Lifetime Test for Optical Transmitters in the ATLAS Liquid Argon Calorimeter Readout System

Accelerated lifetime test has been carried out for 147 days on the custom-made optical transmitters used in the ATLAS Liquid Argon Calorimeter front-end electronics readout system. The lifetime of these optical transmitters is estimated to be greater than 200 years and exceeds the design goal for the LHC. The random failure rate has been estimated at 9.6×10 per hour at 90% confidence level.

متن کامل

The ATLAS liquid argon hadronic end-cap calorimeter: construction and selected beam test results

ATLAS has chosen for its Hadronic End-Cap Calorimeter (HEC) the copper-liquid argon sampling technique with flat plate geometry and GaAs pre-amplifiers in the argon. The contruction of the calorimeter is now approaching completion. Results of production quality checks are reported and their anticipated impact on calorimeter performance discussed. Selected results, such as linearity, electron an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Instrumentation

سال: 2021

ISSN: ['1748-0221']

DOI: https://doi.org/10.1088/1748-0221/16/08/p08006