Quality control of storage phosphor digital radiography systems

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A flat-panel detector digital radiography and a storage phosphor computed radiography: screening for pneumoconioses.

Storage phosphor computed radiography (SR) and flat-panel detector (FPD) radiography are two types of digital X-ray utilizing different techniques. We compared these two techniques with conventional analogue chest radiograph (AR) among pneumoconiotic patients and healthy controls. Thirty individuals consisting of 20 silica-exposed ex-workers and 10 healthy controls without occupational exposure...

متن کامل

A comparison of panoramic image quality between a digital radiography storage phosphor system and a film-based system.

AIM To compare digital panoramic images acquired for the presurgical assessment of third molars captured with a storage phosphor-based system with conventional film panoramic radiographs. METHODS AND MATERIALS A total of 51 pairs of digital and conventional panoramic images, made simultaneously, were included in this study. The images were evaluated for diagnostic quality prior to third molar...

متن کامل

The Practice of Chest Radiography Using Different Digital Imaging Systems: Dose and Image Quality

Introduction: The study was undertaken to evaluate the practice of chest radiography using different digital imaging systems and its influence on dose and image quality.  Materials and Methods: The study was carried out in two hospitals from March 2016 to June 2016. Sixty ambulatory patients aged 21 to 60 years who were able to cooperate without difficulty and weighed between 60 to 80 kg were ...

متن کامل

Comparison of storage phosphor computed radiography with conventional film-screen radiography in the recognition of pneumoconiosis.

Traditional film-screen radiography (FSR) has been useful in the recognition and evaluation of interstitial lung diseases, but is becoming increasingly obsolete. To evaluate the applicability of storage phosphor digital computed radiography (CR) images in the recognition of small lung opacities, we compared image quality and the profusion of small opacities between FSR and CR radiographs. We sc...

متن کامل

Evaluation of a quality control phantom for digital chest radiography

RATIONALE AND OBJECTIVES To examine the effectiveness and suitability of a quality control (QC) phantom for a routine QC program in digital radiography. MATERIALS AND METHODS The chest phantom consists of copper and aluminum cutouts arranged to resemble the appearance of a chest. Performance of the digital radiography (DR) system is evaluated using high and low contrast resolution objects pla...