Pyrolytic and Non-Pyrolytic Boron Nitride Furnaces Electrothermal Atomic Absorption Spectrometry.
نویسندگان
چکیده
منابع مشابه
Photoluminescence properties of pyrolytic boron nitride
We report on spectroscopic study of pyrolytic hBN (pBN) by means of time-and energy-resolved photoluminescence methods. A high purity of pBN samples (though low crystallinity) allows complementary information about excited states involved into the luminescence process. We affirm our recent conclusions about the impurity-related nature of most of the fluorescence bands in microcrystalline hBN. I...
متن کاملPyrolytic and non-pyrolytic boron nitride platforms in electrothermal AAS for the determination of cadmium in sea and estuarine water without chemical modification.
The analytical performance of pyrolytic and non-pyrolytic boron nitride (PBN and NBN) platforms, attached to a commercially available graphite tube furnace, in electrothermal atomic absorption spectrometry (ETAAS) for Cd was studied. Although the tolerable pyrolysis temperature was 300 degrees C with the conventional pyrolytic graphite platform, it increased to 600 and 950 degrees C with the PB...
متن کاملMicrowave absorption properties of pyrolytic carbon nanofilm
We analyzed the electromagnetic (EM) shielding effectiveness in the Ka band (26 to 37 GHz) of highly amorphous nanometrically thin pyrolytic carbon (PyC) films with lateral dimensions of 7.2 × 3.4 mm2, which consists of randomly oriented and intertwined graphene flakes with a typical size of a few nanometers. We discovered that the manufactured PyC films, whose thickness is thousand times less ...
متن کاملQuantification of vanadium in serum by electrothermal atomic absorption spectrometry.
We describe an ultrasensitive and reliable method for determining vanadium in human serum by electrothermal atomic absorption spectrometry. After lyophilization, the serum is digested in acid at high pressure, and the digests are evaporated to a small volume. Vanadium in the digests is complexed with cupferron, extracted, and dried. The residue is redissolved in formic acid, where it is 15-fold...
متن کاملDetermination of cadmium in wine by electrothermal atomic absorption spectrometry.
A method is described for direct electrothermal atomic absorption spectrometric (ETAAS) determination of cadmium in untreated samples of wine. Pyrolytic graphite tubes and graphite tubes with standard L'vov pyrolytic platforms were tested as atomizers. The detection limit achieved was 0.08 microg L(-1) Cd in wine. The relative standard deviation for the concentration range from 0.2 to 10 microg...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical Sciences
سال: 1998
ISSN: 0910-6340,1348-2246
DOI: 10.2116/analsci.14.589