PVC Membrane Sensors for Potentiometric Determination of Acebutolol
نویسندگان
چکیده
منابع مشابه
PVC Membrane Sensors for Potentiometric Determination of Acebutolol
The construction and general performance characteristics of two novelpotentiometric membrane sensors responsive to the acebutolol are described. Thesensors are based on the use of ion-association complexes of acebutolol (AC) withtetraphenylborate(TPB) (I) and phosphomolybdate(PM) (II) as exchange sites in a PVCmatrix. The sensors show a fast, stable and near- Nernstian for the mono charge catio...
متن کاملClomipramine Determination by Potentiometric PVC Membrane and Carbon Paste Sensors
Clomipramine hydrochloride, active component of an antidepressant drug, was determined in the pharmaceutical formulation by two kinds of potentiometric sensor; a PVC membrane sensor and a carbon paste electrode modified by MWCNTs and ionic liquid. Both sensors were corporated with clomipramine-tetraphenylborate ion-pair complex and they respond based on ion exchange mechanism. The best PVC memb...
متن کاملIonophore-based potentiometric PVC membrane sensors for determination of phenobarbitone in pharmaceutical formulations.
The fabrication and development of two polyvinyl chloride (PVC) membrane sensors for assaying phenobarbitone sodium are described. Sensors 1 and 2 were fabricated utilizing β- or γ-cyclodextrin as ionophore in the presence of tridodecylmethylammonium chloride as a membrane additive, and PVC and dioctyl phthalate as plasticizer. The analytical parameters of both sensors were evaluated according ...
متن کاملPotentiometric determination of moxifloxacin in some pharmaceutical formulation using PVC membrane sensors
BACKGROUND The construction and electrochemical response characteristics of Poly (vinyl chloride) membrane sensors for moxifloxacin HCl (MOX) are described. The sensing membranes incorporate ion association complexes of moxifloxacin cation and sodium tetraphenyl borate (NaTPB) (sensor 1), phosphomolybdic acid (PMA) (sensor 2) or phosphotungstic acid (PTA) (sensor 3) as electroactive materials. ...
متن کاملPotentiometric determination of dopamine in pharmaceutical preparations by crown ether-PVC membrane sensors.
Two simple, rapid and sensitive sensors for the assay of dopamine hydrochloride have been developed. The methods are based upon the formation of the membrane sensors 12-crown-4-phosphotungestic acid (crown ether-PTA)-dopamine and 12-crown-4-tetraphenylborate (crown ether-TPB)-dopamine as neutral carriers. The sensors were stable and showed fast potential responses of 10 s, and near-Nernstian ca...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sensors
سال: 2007
ISSN: 1424-8220
DOI: 10.3390/s7123272