Pushing point-spread function reconstruction to the next level: application to SPHERE/ZIMPOL
نویسندگان
چکیده
منابع مشابه
Edge Artifacts in Point Spread Function-based PET Reconstruction in Relation to Object Size and Reconstruction Parameters
Objective(s): We evaluated edge artifacts in relation to phantom diameter and reconstruction parameters in point spread function (PSF)-based positron emission tomography (PET) image reconstruction.Methods: PET data were acquired from an original cone-shaped phantom filled with 18F solution (21.9 kBq/mL) for 10 min using a Biograph mCT scanner. The images were reconstructed using the baseline or...
متن کاملEvaluation of the Effect of Tumor Position on Standardized Uptake Value Using Time-of-Flight Reconstruction and Point Spread Function
Objective(s): The present study was conducted to examine whether the standardized uptake value (SUV) may be affected by the spatial position of a lesion in the radial direction on positron emission tomography (PET) images, obtained via two methods based on time-of-flight (TOF) reconstruction and point spread function (PSF). Methods: A cylinder phantom with the sphere (30mm diameter), located in...
متن کاملKeck Next Generation Adaptive Optics Point Spread Function (NGAO-PSF) Metrics, Characterization, and Reconstruction
We summarize discussions among the key science case authors to determine cost-benefit trade-offs (also known as “metrics”) related to the PSF seen by the science instrument (Davinci).. In section 2 we summarize discussions related to the potential scientific benefit of characterizing the shape and the stability of the PSF. In section 3 we discuss reconstruction. In conclusion, in section 4, we ...
متن کاملBlind reconstruction of sparse images with unknown point spread function
We consider the image reconstruction problem when the original image is assumed to be sparse and when partial knowledge of the point spread function (PSF) is available. In particular, we are interested in recovering the magnetization density given magnetic resonance force microscopy (MRFM) data, and we present an iterative alternating minimization algorithm (AM) to solve this problem. A smoothi...
متن کاملPoint spread function based image reconstruction in optical projection tomography.
As a result of the shallow depth of focus of the optical imaging system, the use of standard filtered back projection in optical projection tomography causes space-variant tangential blurring that increases with the distance to the rotation axis. We present a novel optical tomographic image reconstruction technique that incorporates the point spread function of the imaging lens in an iterative ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Monthly Notices of the Royal Astronomical Society
سال: 2020
ISSN: 0035-8711,1365-2966
DOI: 10.1093/mnras/staa525